两点法测量时间调制传递函数
结果显示两种方法估计的TMTF参数峰值敏感度Lps和截止频率fcutoff高度相关,相关系数分别为0.91和0.89,且无固定或比例偏倚;两点法测量时间约10分钟,约为传统方法的三分之一。结论认为两点法可使TMTF测量进入临床诊断。
要点
- 两点法估计的TMTF参数与传统法高度相关(Lps r=0.91,fcutoff r=0.89)。
- 两点法测量时间约10分钟,约为传统方法的三分之一。
- 两点法无固定或比例偏倚,且不受受试者特征系统偏倚影响。
核心结论
- 两点法可估计TMTF参数,并使TMTF测量有望用于临床诊断。
主要发现
- 传统法与两点法估计的Lps相关系数为0.91(t(45)=14.3;p<10),fcutoff相关系数为0.89(t(45)=13.2;p<10)。
- 两种方法之间无固定和比例偏倚,估计值一致性良好。
- 两点法测量时间约10分钟,约为传统方法的三分之一。
关键数值与推荐
- TMTF参数包括峰值敏感度Lps和截止频率fcutoff。
- 两点法与传统法估计的Lps相关系数0.91,fcutoff相关系数0.89,均无固定和比例偏倚。
- 两点法测量时间约10分钟,约为传统方法的三分之一。
临床怎么用
- 在临床诊断和助听器调试中,可考虑用两点法快速估计TMTF以评估时间分辨率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The temporal modulation transfer function (TMTF) has been proposed to estimate the temporal resolution abilities of listeners with normal hearing and listeners with hearing loss. The TMTF data of patients would be useful for clinical diagnosis and for adjusting the hearing instruments at clinical and fitting sites. However, practical application is precluded by the long measurement time of the conventional method, which requires several measurement points. This article presents a new method to measure the TMTF that requires only two measurement points. DESIGN: Experiments were performed to estimate the TMTF of normal listeners and listeners with hearing loss to demonstrate that the two-point method can estimate the TMTF parameter and the conventional method. Sixteen normal hearing and 21 subjects with hearing loss participated, and the difference between the estimated TMTF parameters and measurement time were compared. RESULTS: The TMTF parameters (the peak sensitivity Lps and cutoff frequency fcutoff) estimated by the conventional and two-point methods showed significantly high correlations: the correlation coefficient for Lps was 0.91 (t(45) = 14.3; p < 10) and that for fcutoff was 0.89 (t(45) = 13.2; p < 10). There were no fixed and proportional biases. Therefore, the estimated values were in good agreement. Moreover, there was no systematic bias depending on the subject's profile. The measurement time of the two-point method was approximately 10 min, which is approximately one-third that of the conventional method. CONCLUSION: The two-point method enables the introduction of TMTF measurement in clinical diagnosis.
引用
- Morimoto T, Irino T, Harada K, et al. Two-Point Method for Measuring the Temporal Modulation Transfer Function. Ear Hear. 2019. PMID: 29664752. doi:10.1097/AUD.0000000000000590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。