文献速递鼻科

标准FESS术中隐匿性脑脊液漏的发生情况

Occurrence of occult CSF leaks during standard FESS procedures.
PubMed 文献 · Rhinology · 2018-01-01

前瞻性队列研究分析57份FESS术中样本,采用水凝胶6 β2-转铁蛋白检测,发现隐匿性脑脊液漏发生率为13%。血液污染条件下常规β2-转铁蛋白检测灵敏度低,随访超过1年所有样本转阴且无临床相关脑脊液漏或脑膜炎发生。

要点

  • FESS术中隐匿性脑脊液漏发生率为13%。
  • 血液污染时常规β2-转铁蛋白检测灵敏度低,不应在此条件下使用。
  • 隐匿性脑脊液漏患者随访超过1年临床过程平稳。

核心结论

  • FESS术中及术后短期内隐匿且临床无关的脑脊液漏在相当比例患者中发生。
  • 血液污染条件下常规β2-转铁蛋白检测灵敏度低,不应在此类场景使用。
  • 隐匿性脑脊液漏患者随访超过1年临床过程平稳,无临床相关脑脊液漏或脑膜炎发生。

研究设计与样本

  • 前瞻性队列研究,分析57份FESS术中样本,采用水凝胶6 β2-转铁蛋白检测。
  • 对脑脊液阳性且持续鼻漏者,超过1年后重新分析。
  • 对原发自发性脑脊液漏样本进行体内分析,并自行滴定评估血液污染条件下β2-转铁蛋白和β-trace蛋白检测的脑脊液检测限。

主要发现

  • FESS术后隐匿性脑脊液漏发生率为13%。
  • 血液污染条件下常规β2-转铁蛋白检测灵敏度低。
  • 随访超过1年所有样本脑脊液检测阴性,无临床相关脑脊液漏或脑膜炎发生。

临床怎么用

  • FESS术中及术后短期内应警惕隐匿性脑脊液漏的可能。
  • 血液污染条件下不应使用常规β2-转铁蛋白检测来诊断脑脊液漏。
  • 对隐匿性脑脊液漏患者可考虑随访观察,其临床过程可能平稳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine the incidence of occult cerebrospinal fluid leaks (CSF) after functional endoscopic sinus surgery (FESS) and to evaluate the diagnostic performance of beta2-transferrin in blood-contaminated conditions. STUDY DESIGN: Prospective cohort study. METHODS: An analysis of 57 intraoperative samples using hydrogel 6 beta2-transferrin assay after FESS was undertaken. In case of CSF positive samples and continuing rhinorrhea, reanalysis after more than 1 year was conducted. In-vivo analysis of a primary spontaneous CSF leak sample took place to verify difficulties in detecting beta2-transferrin in blood-contaminated settings. Own titrations were performed to evaluate detection limits of CSF by beta2-transferrin and beta-trace protein assays in these settings. RESULTS: An incidence of 13% for occult CSF leaks after FESS was found. In blood-contaminated conditions, routine beta2-transferrin assays showed low sensitivity. In over 1 year follow-up, all samples were negative for CSF and none of them developed clinical relevant CSF leaks or meningitis. CONCLUSION: Occult and clinically irrelevant CSF leaks do occur in a significant proportion of patients during and shortly after FESS. Intra- and postoperatively, routine beta2-transferrin assays show low sensitivity. They should not be used in these settings. The clinical course of patients with occult CSF leaks indicated possibility of an uneventful follow-up.

来源:Rhinology,查看原文。版权归原作者所有。

引用

  1. Bucher S, Kugler A, Probst E, et al. Occurrence of occult CSF leaks during standard FESS procedures. Rhinology. 2018. PMID: 29550855. doi:10.4193/Rhin17.117

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。