文献速递耳科与耳神经

耳蜗外电耳蜗图监测人工耳蜗植入过程中的反应变化

Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography.
PubMed 文献 · Ear Hear · 2018-01-01

本研究在83例人工耳蜗植入患者中,比较圆窗与耳蜗外记录位置的电耳蜗图信号强度,并在63例植入过程中持续监测。结果显示约61%病例反应损失在5 dB以内,提示无创植入;部分病例出现反应下降后部分或完全恢复,且恢复者下降多发生在插入早期(<15 mm)。

要点

  • 耳蜗外电耳蜗图可术中监测耳蜗功能,反应损失≤5 dB提示无创植入。
  • 插入中反应下降后恢复者,下降多发生在插入早期(<15 mm)。
  • 反应相位变化可能反映参与反应的发生器分布改变。

核心结论

  • 耳蜗外部位记录电耳蜗图可区分潜在无创植入、反应下降后恢复以及反应损失持续至记录结束三种情况。

研究设计与样本

  • 在83例人类受试者中,于圆窗和耳蜗外位置(镫骨邻近或圆窗上方鼓岬)记录90 dB nHL短纯音反应。
  • 其中63例在人工耳蜗插入过程中从固定耳蜗外位置持续记录。

主要发现

  • 植入前,圆窗对低频短纯音的反应比任一耳蜗外部位大约6 dB,而两个耳蜗外部位之间无差异。
  • 插入过程中,约61%(38/63)病例从鼓岬或镫骨邻近记录的反应损失保持在5 dB以内。
  • 反应下降超过5 dB的病例中,12例无反应恢复,13例在插入结束前出现部分或完全恢复。
  • 有恢复的病例中,反应下降相对较早(<15 mm插入), compared to those where there was no recovery。
  • 部分病例插入过程中出现反应相位变化,可能提示参与反应的发生器分布改变。

临床怎么用

  • 耳蜗外电耳蜗图可作为术中监测耳蜗功能的手段,帮助识别潜在无创植入及可逆性反应变化。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Electrocochleography is increasingly being utilized as an intraoperative monitor of cochlear function during cochlear implantation (CI). Intracochlear recordings from the advancing electrode can be obtained through the device by on-board capabilities. However, such recordings may not be ideal as a monitor because the recording electrode moves in relation to the neural and hair cell generators producing the responses. The purposes of this study were to compare two extracochlear recording locations in terms of signal strength and feasibility as intraoperative monitoring sites and to characterize changes in cochlear physiology during CI insertion. DESIGN: In 83 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then at an extracochlear position-either adjacent to the stapes or on the promontory just superior to the RW. Recording from the fixed, extracochlear position continued during insertion of the CI in 63 cases. RESULTS: Before CI insertion, responses to low-frequency tones at the RW were roughly 6 dB larger than when recording at either extracochlear site, but the two extracochlear sites did not differ from one another. During CI insertion, response losses from the promontory or adjacent to the stapes stayed within 5 dB in ≈61% (38/63) of cases, presumably indicating atraumatic insertions. Among responses which dropped more than 5 dB at any time during CI insertion, 12 subjects showed no response recovery, while in 13, the drop was followed by partial or complete response recovery by the end of CI insertion. In cases with recovery, the drop in response occurred relatively early (<15 mm insertion) compared to those where there was no recovery. Changes in response phase during the insertion occurred in some cases; these may indicate a change in the distributions of generators contributing to the response. CONCLUSIONS: Monitoring the electrocochleography during CI insertion from an extracochlear site reveals insertions that are potentially atraumatic, show interaction with cochlear structures followed by response recovery, or show interactions such that response losses persist to the end of recording.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Giardina CK, Khan TE, Pulver SH, et al. Response Changes During Insertion of a Cochlear Implant Using Extracochlear Electrocochleography. Ear Hear. 2018. PMID: 29554036. doi:10.1097/AUD.0000000000000571

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。