文献速递耳科与耳神经小儿耳鼻咽喉

优化婴儿畸变产物耳声发射的临床解读

Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants.
PubMed 文献 · Ear Hear · 2018-01-01

本研究前瞻性纵向纳入279名听力正常或听力损失婴儿,分析DPOAE水平与信噪比预测听力状态的价值。结果显示中高频(3-8 kHz)测试性能最佳,多频率分析可提高敏感性,宽频吸收率有助于识别传导性成分。

要点

  • DPOAE在2-8 kHz预测听力损失性能较好,1-1.5 kHz性能差。
  • 多频率分析可平衡敏感性与特异性,尤其对感音神经性或混合性听力损失。
  • 宽频吸收率可辅助识别传导性听力损失成分。

核心结论

  • 使用年龄适切的正常范围和优化截断值可改善婴儿DPOAE的临床解读。
  • DPOAE在较高F2测试频率(2-8 kHz)预测性能最佳,1-1.5 kHz性能差。
  • 多频率规则可提高敏感性并平衡特异性。
  • 应纳入敏感的宽频吸收率以评估传导性成分。

研究设计与样本

  • 前瞻性纵向研究,纳入279名来自辛辛那提健康婴儿室和两个新生儿重症监护室的婴儿。
  • 约1月龄时测量DPOAE(1-8 kHz)、宽频吸收率(0.25-8 kHz)及气骨导听性脑干反应阈值(0.5-4 kHz)。
  • 约9月龄时用视觉强化测听(0.5-4 kHz)验证听力状态。

主要发现

  • 单频率DPOAE测试性能在中高频(3-8 kHz)最佳,1.5和2 kHz中等,1 kHz为机会水平。
  • 传导性听力损失(CHL和MHL合并)婴儿的宽频吸收率显著低于听力正常组。
  • 听力正常组与感音神经性听力损失组间宽频吸收率无差异。
  • 多频率分析对SNHL/MHL组预测最佳,纳入CHL婴儿时敏感性较差。

临床怎么用

  • 临床解读婴儿DPOAE应使用年龄适切的正常范围和优化截断值。
  • 优先关注2-8 kHz的DPOAE结果,谨慎解读1-1.5 kHz。
  • 采用多频率规则平衡敏感性与特异性。
  • 结合宽频吸收率评估传导性听力损失可能性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. DESIGN: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. RESULTS: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. CONCLUSIONS: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Blankenship CM, Hunter LL, Keefe DH, et al. Optimizing Clinical Interpretation of Distortion Product Otoacoustic Emissions in Infants. Ear Hear. 2018. PMID: 29517520. doi:10.1097/AUD.0000000000000562

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。