文献速递咽喉与嗓音

使用穿透式电极阵列选择性刺激猫喉返神经的研究

Selective recurrent laryngeal nerve stimulation using a penetrating electrode array in the feline model.
PubMed 文献 · Laryngoscope · 2017-10-31

该研究在6只麻醉猫中,将多通道穿透式微电极阵列植入喉返神经,通过独立通道刺激选择性激活限制性神经纤维群,引发特定喉肌收缩,并记录肌电电压和视频喉镜观察声带运动;在神经损伤模型中亦验证了该能力。

要点

  • 穿透式微电极阵列可选择性刺激猫喉返神经内限制性纤维群。
  • 通过选择适当刺激通道,单次放置即可选择性收缩单个喉肌。
  • 损伤模型实验中亦证实该电极阵列能选择性引发离散喉肌收缩。

核心结论

  • 穿透式微电极阵列能够选择性刺激猫喉返神经内限制性纤维群,并在急性和损伤模型中引发离散喉肌收缩,提示神经内微电极阵列植入在声带麻痹管理中具有潜在作用。

研究设计与样本

  • 急性动物实验,共纳入6只麻醉猫:4只植入未损伤喉返神经,1只接受标准化止血钳挤压伤,1只在测试前4个月接受切断再吻合伤。

主要发现

  • 通过单个通道刺激可选择性激活限制性神经群,导致单个喉肌选择性收缩。
  • 增加电流水平导致肌电电压反应升高。
  • 通常通过单次放置微电极阵列并选择适当刺激通道即可成功激活单个肌肉。
  • 视频喉镜主要观察到声带外展。
  • 神经组织学证实了喉返神经挤压伤和切断实验中的损伤。

临床怎么用

  • 该技术可能为声带麻痹提供一种生物电刺激治疗途径,但尚需进一步研究验证。

局限性

  • 研究为猫急性实验,样本量小(6只),结论外推至人类需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: Laryngeal muscles (LMs) are controlled by the recurrent laryngeal nerve (RLN), injury of which can result in vocal fold (VF) paralysis (VFP). We aimed to introduce a bioelectric approach to selective stimulation of LMs and graded muscle contraction responses. STUDY DESIGN: Acute experiments in cats. METHODS: The study included six anesthetized cats. In four cats, a multichannel penetrating microelectrode array (MEA) was placed into an uninjured RLN. For RLN injury experiments, one cat received a standardized hemostat-crush injury, and one cat received a transection-reapproximation injury 4 months prior to testing. In each experiment, three LMs (thyroarytenoid, posterior cricoarytenoid, and cricothyroid muscles) were monitored with an electromyographic (EMG) nerve integrity monitoring system. Electrical current pulses were delivered to each stimulating channel individually. Elicited EMG voltage outputs were recorded for each muscle. Direct videolaryngoscopy was performed for visualization of VF movement. RESULTS: Stimulation through individual channels led to selective activation of restricted nerve populations, resulting in selective contraction of individual LMs. Increasing current levels resulted in rising EMG voltage responses. Typically, activation of individual muscles was successfully achieved via single placement of the MEA by selection of appropriate stimulation channels. VF abduction was predominantly observed on videolaryngoscopy. Nerve histology confirmed injury in cases of RLN crush and transection experiments. CONCLUSIONS: We demonstrated the ability of a penetrating MEA to selectively stimulate restricted fiber populations within the feline RLN and selectively elicit contractions of discrete LMs in both acute and injury-model experiments, suggesting a potential role for intraneural MEA implantation in VFP management. LEVEL OF EVIDENCE: NA. Laryngoscope, 128:1606-1614, 2018.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Haidar YM, Sahyouni R, Moshtaghi O, et al. Selective recurrent laryngeal nerve stimulation using a penetrating electrode array in the feline model. Laryngoscope. 2017. PMID: 29086427. doi:10.1002/lary.26969

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。