感音神经性听力损失患者中枢听觉通路的弥散张量成像:系统综述
本系统综述纳入20篇文献,总结弥散张量成像(DTI)在检测感音神经性听力损失患者中枢听觉通路结构改变中的价值。听觉皮层和下丘是最常研究的区域,多数病例的弥散指标(如各向异性分数)较正常听力对照存在改变。结论认为DTI可显示白质改变,但研究数量少、样本量有限,需进一步标准化。
要点
- DTI可显示感音神经性听力损失患者中枢听觉通路的白质微结构改变。
- 听觉皮层和下丘是最常被研究的区域,多数病例弥散指标有改变。
- 研究数量少、样本量有限,DTI标准化和前瞻性大样本研究有待开展。
核心结论
- 基于DTI指标的White matter改变可见于感音神经性听力损失患者,但研究数量少且样本量有限。
- 需要采用前瞻性研究设计和更大样本量进一步标准化DTI。
研究设计与样本
- 系统综述,遵循PRISMA声明清单进行研究设计。
- 检索PubMed、Embase和Cochrane数据库,最终分析20篇文章。
- 纳入标准为至少包含1例感音神经性听力损失患者且具有DTI结局数据的研究。
主要发现
- 双侧听力损失患者占所有受试者的60.8%。
- 其余研究包括单侧或进行性听力损失及耳鸣患者。
- 听觉皮层和下丘是DTI最常研究的区域,多数病例的弥散指标(如各向异性分数)较正常听力对照存在改变。
- 其他听觉区域也报告了可检测的变化,但变异程度更高。
临床怎么用
- DTI可作为揭示感音神经性听力损失患者中枢听觉通路白质微结构改变的影像学手段。
- 目前证据尚不足以支持DTI常规用于临床评估中枢听觉通路。
局限性
- 纳入研究数量少,样本量有限。
- DTI方法缺乏标准化,需前瞻性大样本研究进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective The radiologic evaluation of patients with hearing loss includes computed tomography and magnetic resonance imaging (MRI) to highlight temporal bone and cochlear nerve anatomy. The central auditory pathways are often not studied for routine clinical evaluation. Diffusion tensor imaging (DTI) is an emerging MRI-based modality that can reveal microstructural changes in white matter. In this systematic review, we summarize the value of DTI in the detection of structural changes of the central auditory pathways in patients with sensorineural hearing loss. Data Sources PubMed, Embase, and Cochrane. Review Methods We used the Preferred Reporting Items for Systematic Reviews and Meta-Analysis statement checklist for study design. All studies that included at least 1 sensorineural hearing loss patient with DTI outcome data were included. Results After inclusion and exclusion criteria were met, 20 articles were analyzed. Patients with bilateral hearing loss comprised 60.8% of all subjects. Patients with unilateral or progressive hearing loss and tinnitus made up the remaining studies. The auditory cortex and inferior colliculus (IC) were the most commonly studied regions using DTI, and most cases were found to have changes in diffusion metrics, such as fractional anisotropy, compared to normal hearing controls. Detectable changes in other auditory regions were reported, but there was a higher degree of variability. Conclusion White matter changes based on DTI metrics can be seen in patients with sensorineural hearing loss, but studies are few in number with modest sample sizes. Further standardization of DTI using a prospective study design with larger sample sizes is needed.
引用
- Tarabichi O, Kozin ED, Kanumuri VV, et al. Diffusion Tensor Imaging of Central Auditory Pathways in Patients with Sensorineural Hearing Loss: A Systematic Review. Otolaryngol Head Neck Surg. 2017. PMID: 29112481. doi:10.1177/0194599817739838