文献速递耳科与耳神经

人工耳蜗植入术中影像学检查的系统综述

Utility of intraoperative imaging in cochlear implantation: A systematic review.
PubMed 文献 · Laryngoscope · 2017-10-31

该系统综述检索多个数据库至2017年4月,纳入17项研究,评估人工耳蜗植入术中影像学检查的效用。术中X线在917例植入中显示3.5%位置不满意,94.7%改变了处理;术中CT在69例中显示3.0%位置不满意,均改变处理。多数研究认为术中影像在解剖异常或术者质疑位置时有帮助,但常规影像的效用尚不明确。

要点

  • 术中影像可发现低比例但不可忽视的电极位置不满意。
  • 解剖异常或术者质疑位置时,术中影像最有帮助。
  • 常规术中影像的效用目前证据尚不充分。

核心结论

  • 术中影像能发现人工耳蜗植入术中电极位置不满意,发生率低但不可忽视。
  • 现有文献对常规影像的效用尚无定论,但在耳蜗解剖异常或术者质疑位置时似最有用。

研究设计与样本

  • 系统综述,检索PubMed、EMBASE、Medline、CINAHL和Cochrane图书馆从建库至2017年4月。

主要发现

  • 术中X线在8项研究917例植入中,19例(3.5%)影像显示位置不满意,其中18例(94.7%)改变了处理。
  • 术中CT在7项研究69例植入中,2例(3.0%)影像显示位置不满意,均(100%)改变了处理。

临床怎么用

  • 在耳蜗解剖异常或术者质疑电极位置时,可考虑使用术中影像确认放置。
  • 术中影像发现位置不满意时,多数情况下会改变处理决策。

局限性

  • 纳入研究均非随机对照试验。
  • 现有文献对常规术中影像的效用尚不能得出确定性结论。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Many institutions routinely perform intraoperative imaging during cochlear implant (CI) surgery to determine accurate electrode placement. Different modalities exist; however, there remains some controversy regarding the usefulness of intraoperative imaging. OBJECTIVE: Systematically review the utility of intraoperative imaging in CI surgery and implications for management. METHODS: PubMed, EMBASE, Medline, CINAHL, and Cochrane library were searched from inception to April 2017. Studies analyzing the use of intraoperative imaging during CI surgery were included. Outcome measures included unsatisfactory placement and change in management. Two independent evaluators reviewed each abstract and article. RESULTS: Two hundred and sixty-seven articles were identified. Of those, 17 met inclusion criteria. There were no randomized controlled trials. Intraoperative X-rays were performed in 917 CIs in eight studies. Placement was unsatisfactory on radiograph in 19 implants (3.5%), and management was changed in 18 of 19 (94.7%). Intraoperative computed tomography (CT) was performed in 69 CIs in seven studies. Placement was unsatisfactory on CT in two implants (3.0%), and management was changed in both (100%). Intraoperative real-time fluoroscopy was performed in 20 CIs in two studies to help guide correct placement. Twenty-two of these patients had abnormal cochleas. Fifteen out of 17 studies concluded that intraoperative imaging is useful, especially with challenging anatomy or when the surgeon questions placement. CONCLUSION: Intraoperative imaging detects unsatisfactory placement of electrodes during CI surgery at a low, but not negligible, rate. The current literature is not conclusive regarding the utility of routine imaging, but it appears to be most useful with abnormal cochlear anatomy or when the surgeon questions placement. LEVEL OF EVIDENCE: NA. Laryngoscope, 1914-1921, 2018.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Appachi S, Schwartz S, Ishman S, et al. Utility of intraoperative imaging in cochlear implantation: A systematic review. Laryngoscope. 2017. PMID: 29086418. doi:10.1002/lary.26973

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。