清醒内镜与CT定义舌扁桃体肥大的比较
结果显示内镜LTG 3级的LTT显著大于LTG 1和2级,轴位和矢状位CT约7.5 mm可能作为临床显著舌扁桃体肥大的切点。
要点
- 清醒内镜舌扁桃体分级与CT测量的舌扁桃体厚度具有相关性。
- LTG 3级的轴位和矢状位CT厚度均显著大于LTG 1和2级。
- 轴位和矢状位CT约7.5 mm可能提示临床显著舌扁桃体肥大。
核心结论
- 清醒内镜舌扁桃体肥大分级是主观测量,但似乎与客观CT测量相关。
- 内镜LTG 1和LTG 2的LTT测量值与LTG 3显著不同。
研究设计与样本
- 回顾性病历审查,单中心数据库,2016年9月至2017年4月。
- 在轴位和矢状位CT上测量LTT,并与内镜LTG比较,采用单因素方差分析和Tukey事后检验。
主要发现
- 轴位CT:LTG 1与LTG 3、LTG 2与LTG 3差异均显著(P < .001),LTG 1与LTG 2差异显著(P = .010)。
- 矢状位CT:LTG 1与LTG 3差异显著(P < .001),LTG 2与LTG 3差异显著(P = .002),LTG 1与LTG 2差异不显著(P = .186)。
- 无舌扁桃体肥大者平均轴位CT厚度6.45 ± 1.39 mm、矢状位6.58 ± 1.53 mm,与LTG 3组平均轴位8.48 ± 1.52 mm、矢状位8.07 ± 1.16 mm差异均显著(P < .001)。
- 阈值分析显示轴位和矢状位CT约7.5 mm可能作为定义临床显著舌扁桃体肥大的切点。
关键数值与推荐
- 内镜LTG采用Friedman舌扁桃体肥大分级系统。
- 轴位和矢状位CT约7.5 mm为潜在切点。
临床怎么用
- 清醒内镜分级可作为舌扁桃体肥大的主观评估工具,与CT客观测量相关。
- CT测量舌扁桃体厚度(尤其约7.5 mm切点)可能辅助识别临床显著舌扁桃体肥大。
局限性
- 回顾性单中心设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objectives To analyze correlations between endoscopic lingual tonsil grade (LTG) by the Friedman Lingual Tonsil Hypertrophy grading system and computed tomography (CT) measurements of lingual tonsil thickness (LTT). Study Design Retrospective chart review. Setting Single-center database, September 2016 to April 2017. Subjects and Methods Patients who received CT covering base of tongue and endoscopic LTG were included. LTT was measured on axial and sagittal CT. LTT measurements were compared against endoscopic LTG. One-way analysis of variance with Tukey's post hoc adjustment for multiple comparisons was performed. Results Seventy-five charts were included for a total of 150 LTT measurements. Axial CT measurements of LTG 1 and LTG 2 were each significantly different from LTG 3 ( P < .001 for both), and LTG 1 and LTG 2 also differed significantly ( P = .010). Mean sagittal CT measurements were significantly different between LTG 1 and LTG 3 ( P < .001) and between LTG 2 and LTG 3 ( P = .002) but not between LTG 1 and LTG 2 ( P = .186). Those without lingual tonsil hypertrophy had a mean axial CT thickness of 6.45 ± 1.39 mm and mean sagittal CT thickness of 6.58 ± 1.53 mm, which was significantly different from both the mean axial CT thickness of 8.48 ± 1.52 mm and the mean sagittal CT thickness of 8.07 ± 1.16 mm in the LTG 3 group ( P < .001 for both). Threshold analysis showed a potential cutoff of approximately 7.5 mm on axial and sagittal CT for defining clinically significant lingual tonsil hypertrophy. Conclusion Awake endoscopy grading of lingual tonsil hypertrophy is a subjective measurement that seems to correlate with objective CT measurements. LTT measurements of LTG 1 and LTG 2 on awake endoscopy differed significantly from LTG 3.
引用
- Tang JA, Gorelick G, Friedman M, et al. Comparison between Awake Endoscopy and Computed Tomography to Define Lingual Tonsil Hypertrophy. Otolaryngol Head Neck Surg. 2017. PMID: 28949799. doi:10.1177/0194599817731731
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。