文献速递咽喉与嗓音

甲状软骨下入路声带内移术的离体犬喉评估

Excised larynx evaluation of subthyroid cartilage approach to medialization thyroplasty.
PubMed 文献 · Laryngoscope · 2017-09-11

本研究在八只离体犬喉上比较正常、麻痹、传统经甲状软骨入路和实验性甲状软骨下入路Gore-Tex植入内移术的嗓音学效果。两种入路均较麻痹状态显著降低发声阈值压力和发声阈值气流,改善声学参数并保留黏膜波,除发声阈值气流外两组间无显著差异。甲状软骨下入路无需制作甲状软骨窗,可能是有价值的替代方法。

要点

  • 甲状软骨下入路Gore-Tex植入可有效内移声带并保留黏膜波。
  • 两种入路均改善发声阈值压力、气流及声学参数。
  • 除发声阈值气流外,两种入路嗓音学指标无显著差异。

核心结论

  • 离体犬喉模型中,经甲状软骨下入路植入Gore-Tex可有效内移声带、保留黏膜波并显著改善气动力学和声学参数。
  • 除发声阈值气流外,甲状软骨下入路与传统经甲状软骨入路在各项发声指标上无显著差异。
  • 甲状软骨下入路无需制作甲状软骨窗,可能是有价值的声带内移术替代方法。

研究设计与样本

  • 动物模型研究,使用八只离体犬喉。
  • 每只喉依次测试正常、麻痹、传统经甲状软骨入路内移术和实验性甲状软骨下入路内移术四种条件。

主要发现

  • 与声带麻痹状态相比,两种入路植入Gore-Tex均显著降低发声阈值压力和发声阈值气流。
  • 两种入路均显著降低jitter百分比、降低shimmer百分比并改善信噪比。
  • 两种入路植入Gore-Tex后黏膜波均得以保留。
  • 除发声阈值气流外,传统经甲状软骨入路与甲状软骨下入路之间各项发声指标无显著差异。

临床怎么用

  • 甲状软骨下入路可作为声带内移术的潜在替代方法,尤其适用于希望避免制作甲状软骨窗的情况。
  • 该入路在离体模型中可保留黏膜波并改善发声气动力学和声学参数。

局限性

  • 研究基于离体犬喉模型,结果不能直接等同于活体人类临床效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: To describe an alternative approach to medialization thyroplasty involving dissection underneath the thyroid cartilage with placement of a Gore-Tex implant, and to evaluate its effect on a range of phonatory measures using an excised canine larynx model. STUDY DESIGN: Animal model. METHODS: On each of eight excised canine larynges, the conditions of normal, paralysis, medialization thyroplasty by standard transthyroid cartilage approach, and medialization thyroplasty by experimental subthyroid cartilage approach were performed. Aerodynamic, acoustic, and mucosal wave parameters were measured for each condition. RESULTS: Compared to the vocal fold paralysis state, both the transthyroid and subthyroid approaches for Gore-Tex insertion resulted in significant decreases in phonation threshold pressure and phonation threshold flow. Both approaches also significantly decreased percent jitter, decreased percent shimmer, and improved signal-to-noise ratio. The mucosal wave was preserved after insertion of the Gore-Tex implant for both approaches. For all the phonatory measures except phonation threshold flow, there were no significant differences between the transthyroid and subthyroid approaches. CONCLUSIONS: Gore-Tex implantation via a subthyroid approach in an excised canine larynx model can produce effective medialization, preserve the mucosal wave, and significantly improve aerodynamic and acoustic parameters without meaningful difference compared to a traditional transthyroid approach. The subthyroid approach does not require creation of a thyroid cartilage window and could be a potentially valuable alternative method of performing medialization thyroplasty. LEVEL OF EVIDENCE: NA. Laryngoscope, 128:675-681, 2018.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Thompson JD, Hoffman MR, Scholp A, et al. Excised larynx evaluation of subthyroid cartilage approach to medialization thyroplasty. Laryngoscope. 2017. PMID: 28891238. doi:10.1002/lary.26852

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。