文献速递鼻科

慢性鼻窦炎不同内镜评分系统的信度、效度、反应性及相关性比较

Comparison of different endoscopic scoring systems in patients with chronic rhinosinusitis: reliability, validity, responsiveness and correlation.
PubMed 文献 · Rhinology · 2017-01-01

该前瞻性研究纳入144例接受功能性内镜鼻窦手术的慢性鼻窦炎患者,术前及术后6个月完成SNOT-22、Lund-Mackay CT评分和内镜评估,由两名盲法鼻科医生用3种评分系统评价内镜视频。结果显示MLK和DIP评分系统具有高重测信度和评分者间信度,且反应性、效度和可靠性良好,适合临床和研究使用。

要点

  • MLK和DIP内镜评分系统在慢性鼻窦炎患者中显示出高重测信度和评分者间信度。
  • MLK和DIP与其他主观评估高度相关,但与SNOT-22无相关性。
  • MLK和DIP具有充分的反应性、效度和可靠性,适合临床与研究使用。

核心结论

  • MLK和DIP内镜评分系统表现出充分的反应性、效度和可靠性,可能很适合临床和研究使用。

研究设计与样本

  • 前瞻性研究纳入144例接受功能性内镜鼻窦手术的慢性鼻窦炎患者。
  • 所有参与者在术前和术后6个月完成SNOT-22、Lund-Mackay CT评分和内镜检查评估。
  • 内镜检查视频由两名盲法鼻科医生使用3种评分系统进行评估。

主要发现

  • MLK和DIP内镜评分系统显示出高重测信度和评分者间信度。
  • 所有内镜评分系统在各时间点记录的评分之间均显示出显著差异(所有P低于0.90,与Lund-Kennedy内镜评分系统比较时)。
  • MLK和DIP评分系统与其他主观评估高度相关,与SNOT-22无相关性。
  • MLK和DIP评分系统在无症状与有症状病例之间的区分效度具有统计学显著差异。

临床怎么用

  • MLK和DIP内镜评分系统可用于慢性鼻窦炎患者的临床评估和研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Previous studies have proposed various endoscopic scoring systems to assess disease severity of patients with chronic rhinosinusitis (CRS). However, those assessments have not been validated. This study was designed to assess the Modified Lund - Kennedy (MLK) and the discharge, inflammation, and polyps/oedema (DIP) endoscopic scoring systems in patients with CRS. METHODS: A prospective study including 144 patients who underwent functional endoscopic sinus surgery (FESS). All participants were asked to finish SNOT-22, Lund-Mackay CT score and endoscopic examination evaluations before surgery and at 6 months after surgery. Endoscopic examination videos were evaluated using 3 scoring systems by two blinded rhinologists. The scores were compared in terms of responsiveness, validity, reliability and correlation with other scores. RESULTS: The MLK and DIP endoscopic scoring systems showed high test-retest reliability and inter-rater reliability. All endoscopic scoring systems showed significant differences between the scores recorded at each time point (all P lower than 0.90 when compared with the Lund - Kennedy (LK) endoscopic scoring system and showed a statistically significant difference in discriminant validity between symptomless and symptomatic cases. The MLK and DIP systems showed high correlations with other subject assessments and no correlation with SNOT-22. CONCLUSION: MLK and DIP exhibit substantial responsiveness, validity and reliability. MLK and DIP may be well suited for clinical and research use.

来源:Rhinology,查看原文。版权归原作者所有。

引用

  1. Zhang L, Zhang LH. Comparison of different endoscopic scoring systems in patients with chronic rhinosinusitis: reliability, validity, responsiveness and correlation. Rhinology. 2017. PMID: 28888025. doi:10.4193/Rhin17.109

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。