智能手机应用测量哭声音量筛查婴儿声带运动障碍
德克萨斯儿童医院ICU的病例对照研究纳入42名婴儿,比较有和无声带运动障碍(VFMI)者的哭声音量。VFMI组平均哭声音量76.60 dB,无VFMI组85.72 dB,差异9.12 dB(95%CI 2.74-15.50 dB)。≥90 dB对识别正常声带运动敏感度90.4%,≤75 dB对识别VFMI特异度90.5%,但哭声音量不能筛查误吸。
要点
- 智能手机距口12英寸测量哭声音量可用于筛查婴儿声带运动障碍。
- 哭声≥90 dB提示声带运动正常,敏感度90.4%。
- 哭声≤75 dB提示VFMI,特异度90.5%,但不能筛查误吸。
核心结论
- 床旁智能手机测量哭声音量可由未经培训的医护人员用于筛查需进一步FNL评估声带运动的婴儿。
研究设计与样本
- 2013年12月1日至2015年1月31日在德克萨斯儿童医院ICU进行的病例对照研究,纳入42名婴儿,21例VFMI和21例无VFMI,基于FNL结果分组。
主要发现
- VFMI组平均哭声音量76.60 dB,无VFMI组85.72 dB,绝对差异9.12 dB(95%CI 2.74-15.50 dB)。
- 哭声音量≥90 dB识别正常声带运动的敏感度为90.4%(95%CI 71%-97%)。
- 哭声音量≤75 dB识别VFMI的特异度为90.5%(95%CI 71%-97%)。
- ROC曲线下面积均值(SE)为0.721(0.080)(95%CI 0.565-0.877)。
- 哭声音量不是筛查误吸的良好指标。
关键数值与推荐
- 哭声音量≥90 dB:识别正常声带运动敏感度90.4%(95%CI 71%-97%)。
- 哭声音量≤75 dB:识别VFMI特异度90.5%(95%CI 71%-97%)。
临床怎么用
- 对ICU婴儿可用智能手机应用距口12英寸测量哭声音量,≥90 dB或≤75 dB时分别提示正常或VFMI,需FNL进一步确认。
局限性
- 样本量42例,为单中心病例对照研究,哭声音量不能筛查误吸。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: Infants with vocal-fold motion impairment (VFMI) have an increased risk of aspiration and pulmonary complications. Flexible nasolaryngoscopy (FNL) is the gold standard for evaluation of vocal-fold mobility. Although safe, FNL causes measurable physiologic changes. Noxious stimuli, especially in neonates in the cardiovascular intensive care unit, may cause imbalance between the pulmonary and systemic circulations and potentially circulatory collapse. OBJECTIVE: To examine whether bedside measurement of infant cry volume using a smartphone application can be a screening tool for vocal-fold movement in FNL. DESIGN, STUDY, AND PARTICIPANTS: This case-control study performed from December 1, 2013, through January 31, 2015, included 42 infants in the intensive care unit at Texas Children's Hospital, Houston. MAIN OUTCOMES AND MEASURES: Patient cry volume in decibels was recorded using a smartphone application placed 12 in from their mouth. RESULTS: Forty-two infants were identified at the intensive care unit (median age, 33 days; 20 [48%] female and 22 [52%] male), 21 with VFMI and 21 without, based on FNL findings. A statistically significant difference was found in the mean cry volume of infants with (76.60 dB) and without (85.72 dB) VFMI. The absolute difference in the mean cry volume was 9.12 dB (95% CI, 2.74-15.50 dB). A cry volume of 90 dB or greater had a sensitivity of 90.4% (95% CI, 71%-97%) for identification of normal vocal-fold mobility. A cry volume of 75 dB or less had a specificity of 90.5% (95% CI, 71%-97%) for the identification of VFMI. The mean (SE) area under the receiver operating characteristic curve was 0.721 (0.080) (95% CI, 0.565-0.877). The cry volume, however, was not a good screen for aspiration. CONCLUSIONS AND RELEVANCE: Bedside measurement of the cry volume with a smartphone application can be used by untrained health care professionals to screen patients for further evaluation of vocal-fold mobility using FNL.
引用
- Liu YC, Varier I, Ongkasuwan J, et al. Use of Audiometric Measurement for Assessment of Vocal-Fold Function in Postextubation Infants. JAMA Otolaryngol Head Neck Surg. 2017. PMID: 28662238. doi:10.1001/jamaoto.2017.0848
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。