术前18F-FDG-PET/CT与增强CT识别头颈鳞癌区域淋巴结转移的比较
按颈部分区和侧别计算,PET/CT敏感度为0.69和0.94,CECT为0.53和0.66;PET/CT特异度为0.86和0.56,CECT为0.91和0.76;总体准确率无显著差异。影像N分期与病理N分期的一致率PET/CT为52%、CECT为55%。结论认为两种检查在治疗前评估中的信息似有互补性。
要点
- 按侧别CECT特异度0.76高于PET/CT的0.56(P=.024)。
- PET/CT与CECT总体准确率无显著差异(P=.33,P=.88)。
核心结论
- PET/CT与CECT的敏感度无显著差异,CECT特异度优于PET/CT,两种检查在HNSCC治疗前评估中的信息似有互补性。
主要发现
- 按颈部分区和侧别,PET/CT敏感度分别为0.69和0.94,CECT为0.53和0.66(P=.056,P=.001)。
- 按颈部分区和侧别,PET/CT特异度分别为0.86和0.56,CECT为0.91和0.76(P=.014,P=.024)。
- 总体准确率无显著差异(P=.33,P=.88)。
- 影像判断的N分期与病理N分期总体一致率:PET/CT为52%,CECT为55%。
关键数值与推荐
- 按颈部分区:PET/CT敏感度0.69、特异度0.86;CECT敏感度0.53、特异度0.91(敏感度P=.056,特异度P=.014)。
- 按侧别:PET/CT敏感度0.94、特异度0.56;CECT敏感度0.66、特异度0.76(敏感度P=.001,特异度P=.024)。
- 总体准确率比较P=.33(分区)与P=.88(侧别),无显著差异。
临床怎么用
- 原文未给出临床应用建议。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective Our objective was to compare the accuracy of preoperative positron emission tomography (PET)/computed tomography (CT) and contrast-enhanced CT (CECT) in detecting cervical nodal metastases in patients treated with neck dissection and to scrutinize the ability of each modality to determine nodal stage. Study Design Case series with chart review. Setting Montefiore Medical Center, Bronx, New York. Subjects and Methods Patients who underwent neck dissection at our institution for primary treatment of head and neck squamous cell carcinoma (HNSCC) and had received preoperative PET/CT and CECT were included in this study. Imaging studies were reinterpreted by 3 specialists within the field and compared for interreader agreement. Concordance between radiology and histopathology was measured using neck levels and sides, along with patient nodal stage. Sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and agreement coefficients were calculated. Results Seventy-three patients were included in the study. Sensitivity was 0.69 and 0.94 (level and side) for PET/CT vs 0.53 and 0.66 for CECT ( P = .056, P = .001). Specificity was 0.86 and 0.56 for PET/CT vs 0.91 and 0.76 for CECT ( P = .014, P = .024). No significant difference was found in overall accuracy ( P = .33, P = .88). The overall agreement percentages between N stage called by imaging modality and pathology were 52% and 55% for PET/CT and CECT, respectively. Conclusion No significant difference in sensitivity was found between PET/CT and CECT. CECT was found to have superior specificity compared with PET/CT. The information gleaned from each modality in the pretreatment evaluation of HNSCC appears to be complementary.
引用
- Cho JK, Ow TJ, Lee AY, et al. Preoperative 18F-FDG-PET/CT vs Contrast-Enhanced CT to Identify Regional Nodal Metastasis among Patients with Head and Neck Squamous Cell Carcinoma. Otolaryngol Head Neck Surg. 2017. PMID: 28608737. doi:10.1177/0194599817703927