文献速递咽喉与嗓音

声带表面电阻在体测量:急性声创伤动物模型概念验证

In vivo measurement of vocal fold surface resistance.
PubMed 文献 · Laryngoscope · 2017-06-02

本研究在兔模型中开发定制探头,在体测量声带表面电阻,以验证其作为急性声创伤后功能组织完整性替代指标的可行性。实验组接受120分钟高强度发声后,表面电阻较基线显著下降,并伴有声带上皮超微结构损伤;对照组电阻稳定且上皮结构保存完好。

要点

  • 定制探头可经喉镜在体测量声带中三分之一表面电阻。
  • 120分钟高强度发声后实验组声带表面电阻较基线显著下降。
  • 电阻下降与声带上皮及基底膜破坏等超微结构损伤相关。

核心结论

  • 在体测量声带表面电阻可作为评估声带上皮屏障功能完整性的可行手段。

研究设计与样本

  • 前瞻性动物研究,使用新西兰白兔,对照组接受120分钟无声带闭合的气流,实验组接受120分钟高强度发声。

主要发现

  • 对照组声带表面电阻各时间点保持稳定。
  • 实验组在120分钟高强度发声后表面电阻较基线显著下降(原文以X%±Y%相对基线表示)。
  • 透射电镜显示实验组声带上皮损伤,包括上皮和基底膜破坏、细胞旁间隙扩张及上皮微突起改变;对照组复层鳞状上皮保存完好。

临床怎么用

  • 该探头原型正在开发中,用于进一步测试、验证及喉科临床应用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES/HYPOTHESIS: A custom-designed probe was developed to measure vocal fold surface resistance in vivo. The purpose of this study was to demonstrate proof of concept of using vocal fold surface resistance as a proxy of functional tissue integrity after acute phonotrauma using an animal model. STUDY DESIGN: Prospective animal study. METHODS: New Zealand White breeder rabbits received 120 minutes of airflow without vocal fold approximation (control) or 120 minutes of raised intensity phonation (experimental). The probe was inserted via laryngoscope and placed on the left vocal fold under endoscopic visualization. Vocal fold surface resistance of the middle one-third of the vocal fold was measured after 0 (baseline), 60, and 120 minutes of phonation. After the phonation procedure, the larynx was harvested and prepared for transmission electron microscopy. RESULTS: In the control group, vocal fold surface resistance values remained stable across time points. In the experimental group, surface resistance (X% ± Y% relative to baseline) was significantly decreased after 120 minutes of raised intensity phonation. This was associated with structural changes using transmission electron microscopy, which revealed damage to the vocal fold epithelium after phonotrauma, including disruption of the epithelium and basement membrane, dilated paracellular spaces, and alterations to epithelial microprojections. In contrast, control vocal fold specimens showed well-preserved stratified squamous epithelia. CONCLUSIONS: These data demonstrate the feasibility of measuring vocal fold surface resistance in vivo as a means of evaluating functional vocal fold epithelial barrier integrity. Device prototypes are in development for additional testing, validation, and for clinical applications in laryngology. LEVEL OF EVIDENCE: NA Laryngoscope, 127:E364-E370, 2017.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Mizuta M, Kurita T, Dillon NP, et al. In vivo measurement of vocal fold surface resistance. Laryngoscope. 2017. PMID: 28573762. doi:10.1002/lary.26715

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。