文献速递鼻科

微光学相干断层扫描评估获得性黏液纤毛清除缺陷

Assessment of acquired mucociliary clearance defects using micro-optical coherence tomography.
PubMed 文献 · Int Forum Allergy Rhinol · 2017-06-28

该研究在体外培养的人鼻窦上皮细胞中,通过1%氧气环境12小时诱导获得性CFTR功能障碍,利用Ussing室评估离子转运,并用新型微光学相干断层扫描(μOCT)评估气道表面液(ASL)、纤毛周围液(PCL)和纤毛摆动频率(CBF)。结果显示缺氧组阿米洛利敏感转运增加而CFTR介导的阴离子转运减少,且μOCT检测到ASL、PCL和CBF均降低,表明μOCT在评估获得性MCC缺陷方面技术可行。

要点

  • 1%氧气12小时诱导HSNE细胞获得性CFTR功能障碍和钠超吸收。
  • 缺氧组阿米洛利敏感转运增加而CFTR介导阴离子转运减少。
  • μOCT检测显示缺氧组ASL、PCL和CBF均显著降低。

核心结论

  • 缺氧诱导的HSNE上皮阴离子转运缺陷对μOCT测量的MCC标志物产生可预测的影响。
  • μOCT成像方法代表技术进步,用于评估影响气道表面的获得性缺陷是可行的。

研究设计与样本

  • 研究采用原代人鼻窦上皮(HSNE)细胞培养,将细胞置于1%氧气环境12小时以诱导获得性CFTR功能障碍。
  • 使用Ussing室进行药理操纵评估离子转运特性,并使用μOCT评估ASL、PCL和CBF。

主要发现

  • 缺氧组阿米洛利敏感转运(ΔISC)为-13.2 ± 0.6 μA/cm2,对照组为-6.5 ± 0.1 μA/cm2(p < 0.01)。
  • 缺氧组CFTR介导的阴离子转运为28.6 ± 0.3 μA/cm2,对照组为36.2 ± 1.6 μA/cm2(p < 0.01)。
  • 缺氧组ASL为5.0 ± 0.4 μm,对照组为9.0 ± 0.9 μm(p < 0.01)。
  • 缺氧组PCL深度为2.5 ± 0.1 μm,对照组为4.8 ± 0.3 μm(p < 0.01)。
  • 缺氧组CBF为8.7 ± 0.3 Hz,对照组为10.2 ± 0.3 Hz(p < 0.01)。

临床怎么用

  • μOCT成像技术可用于评估获得性黏液纤毛清除缺陷,如缺氧导致的CFTR功能障碍。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Dehydration of airway surface liquid (ASL) disrupts normal mucociliary clearance (MCC) in sinonasal epithelium, which may lead to chronic rhinosinusitis (CRS). Abnormal chloride (Cl- ) transport is one such mechanism that contributes to this disorder and can be acquired secondary to environmental perturbations, such as hypoxia at the tissue surface. The objective of this study was to assess the technological feasibility of the novel micro-optical coherence tomography (μOCT) imaging technique for investigating acquired MCC defects in cultured human sinonasal epithelial (HSNE) cells. METHODS: Primary HSNE cell cultures were subjected to a 1% oxygen environment for 12 hours to induce acquired cystic fibrosis transmembrane conductance regulator (CFTR) dysfunction. Ion transport characteristics were assessed with pharmacologic manipulation in Ussing chambers. ASL, periciliary fluid (PCL), and ciliary beat frequency (CBF) were evaluated using μOCT. RESULTS: Amiloride-sensitive transport (ΔISC ) was greater in cultures exposed to hypoxia (hypoxia: -13.2 ± 0.6 μA/cm2 ; control: -6.5 ± 0.1 μA/cm2 ; p < 0.01), whereas CFTR-mediated anion transport was significantly diminished (hypoxia: 28.6 ± 0.3 μA/cm2 ; control: 36.2 ± 1.6 μA/cm2 ; p < 0.01), consistent with acquired CFTR dysfunction and sodium hyperabsorption. Hypoxia diminished all markers of airway surface function microanatomy as observed with μOCT, including ASL (hypoxia: 5.0 ± 0.4 μm; control: 9.0 ± 0.9 μm; p < 0.01) and PCL depth (hypoxia: 2.5 ± 0.1 μm; control: 4.8 ± 0.3 μm; p < 0.01), and CBF (hypoxia: 8.7 ± 0.3 Hz; control: 10.2 ± 0.3 Hz; p < 0.01). CONCLUSION: Hypoxia-induced defects in epithelial anion transport in HSNE led to predictable effects on markers of MCC measured with novel μOCT imaging. This imaging method represents a technological leap forward and is feasible for assessing acquired defects impacting the airway surface.

来源:Int Forum Allergy Rhinol,查看原文。版权归原作者所有。

引用

  1. Tipirneni KE, Grayson JW, Zhang S, et al. Assessment of acquired mucociliary clearance defects using micro-optical coherence tomography. Int Forum Allergy Rhinol. 2017. PMID: 28658531. doi:10.1002/alr.21975

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。