常规长度电极人工耳蜗植入短期与长期听力保留的预测因素
本研究为回顾性综述,纳入196例(225耳)常规长度电极人工耳蜗植入且术前250 Hz气导阈值≤80 dB HL的患者。短期听力保留率为38%(84/225),长期为18%(33/188)。术前残余听力较好、侧壁电极及圆窗/扩大圆窗入路可预测更高的长期功能性听力保留率。
要点
- 短期听力保留率38%,长期18%。
- 术前听力较好预测短期和长期听力保留。
- 侧壁电极和圆窗/扩大圆窗入路与更高长期听力保留相关。
核心结论
- 术前残余听力较好、侧壁电极及圆窗/扩大圆窗入路可预测更高的长期功能性听力保留率。
研究设计与样本
- 回顾性综述,纳入196例(225耳)常规长度电极人工耳蜗植入且术前250 Hz气导阈值≤80 dB HL的患者。
主要发现
- 短期听力保留率为38%(84/225),长期为18%(33/188)。
- 多因素分析显示术前听力较好预测短期(OR: 0.93, 95%CI: 0.91-0.95, P < .001)和长期(OR: 0.94, 95%CI: 0.91-0.97, P < .001)听力保留。
- 短期随访中,侧壁电极和mid-scala电极的听力保留优势比分别为3.4(95%CI: 1.4-8.6, P = .009)和5.6倍(95%CI: 1.8-17.3, P = .003),均高于perimodiolar阵列。
- 长期数据显示,侧壁电极听力保留优于perimodiolar电极(OR: 7.6, 95%CI: 1.6-36.1, P = .01),而mid-scala电极与perimodiolar电极无显著差异(OR: 3.1, 95%CI: 0.4-23.1, P = .28)。
- 单因素分析显示,圆窗/扩大圆窗入路长期听力保留率(21%)高于耳蜗开窗入路(0%)(P = 0.002)。
临床怎么用
- 对于术前250 Hz气导阈值≤80 dB HL的患者,选择侧壁电极和圆窗/扩大圆窗入路可能有利于长期听力保留。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES/HYPOTHESIS: The aims of this study were to investigate short- and long-term rates of hearing preservation after cochlear implantation and identify factors that impact hearing preservation. STUDY DESIGN: Retrospective review. METHODS: Patients undergoing cochlear implantation with conventional-length electrodes and air-conduction thresholds ≤80 dB HL at 250 Hz preoperatively were included. Hearing preservation was defined as air-conduction thresholds ≤80 dB HL at 250 Hz. RESULTS: The sample included 196 patients (225 implants). Overall, the rate of short-term hearing preservation was 38% (84/225), with 18% (33/188) of patients preserving hearing long term. Multivariate analysis showed better preoperative hearing was predictive of hearing preservation at short (odds ratio [OR]: 0.93, 95% confidence interval [CI]: 0.91-0.95, P < .001) and long-term follow-up (OR: 0.94, 95% CI: 0.91-0.97, P < .001). Lateral wall electrodes and mid-scala electrodes had 3.4 (95% CI: 1.4-8.6, P = .009) and 5.6-times (95% CI: 1.8-17.3, P = .003) higher odds of hearing preservation than perimodiolar arrays at short-term follow-up, respectively. Long-term data revealed better hearing preservation for lateral wall (OR: 7.6, 95% CI: 1.6-36.1, P = .01), but not mid-scala (OR: 3.1, 95% CI: 0.4-23.1, P = .28), when compared to perimodiolar electrodes. Round window/extended round window (RW/ERW) approaches were associated with higher rates of long-term hearing preservation (21%) than cochleostomy approaches (0%) (P = 0.002) on univariate analysis. CONCLUSIONS: Better preoperative residual hearing, lateral wall electrodes, and RW/ERW approaches are predictive of higher rates of long-term functional hearing preservation. LEVEL OF EVIDENCE: 4. Laryngoscope, 128:482-489, 2018.
引用
- Wanna GB, O'Connell BP, Francis DO, et al. Predictive factors for short- and long-term hearing preservation in cochlear implantation with conventional-length electrodes. Laryngoscope. 2017. PMID: 28643327. doi:10.1002/lary.26714
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。