文献速递鼻科睡眠呼吸障碍

持续正压通气对鼻通畅性的急性影响

Acute impact of continuous positive airway pressure on nasal patency.
PubMed 文献 · Int Forum Allergy Rhinol · 2017-05-23

结果显示鼻阻塞评分升高、鼻腔容积减少、鼻吸气峰流量下降;合并变应性鼻炎症状者各项鼻参数更差。

要点

  • 20 cmH2O CPAP经鼻2小时使清醒正常人鼻阻塞VAS和NOSE评分升高(p<0.05)。
  • CPAP后声反射鼻测量鼻腔容积减少、鼻吸气峰流量下降(p<0.05)。
  • 合并变应性鼻炎症状者鼻参数显著更差:VAS p=0.001、NOSE p<0.001、PF p<0.001。

核心结论

  • 急性CPAP正压暴露与鼻通畅性的主观和客观下降相关。
  • 有变应性鼻症状者鼻通畅性下降比无这些症状者更严重。

研究设计与样本

  • 经鼻罩由CPAP装置向鼻腔施加20 cmH2O持续气道压力2小时。
  • 使用CPAP前后测量鼻阻塞VAS、改良NOSE量表、声反射鼻测量(AR)和鼻吸气峰流量(PF)。
  • 受试者按有无变应性鼻炎症状分为两组进行分层比较。

主要发现

  • CPAP使用后鼻阻塞VAS评分升高(p<0.05)。
  • CPAP使用后NOSE量表评分升高(p<0.05)。
  • CPAP使用后声反射鼻测量鼻腔容积减少(p<0.05)。
  • CPAP使用后鼻吸气峰流量下降(p<0.05)。
  • 变应性鼻炎组较无变应性鼻炎组鼻阻塞VAS更高(p=0.001)、NOSE评分更高(p<0.001)、PF更低(p<0.001)。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Continuous airflow in the upper airway can cause discomfort, leading to nasopharyngeal complaints. The aim of the present study is to evaluate the acute effects of continuous positive upper-airway pressure on nasal patency in awake normal subjects. METHODS: Twenty-seven adults (17 men; 10 women; age range, 18 to 43 years) were exposed to continuous airway pressure (20 cmH2 O) in the nasal cavity, delivered by a continuous positive airway pressure (CPAP) device through a nasal mask for 2 hours. Visual analogue scale (VAS) of nasal obstruction, Nasal Obstruction Symptom Evaluation (NOSE) modified scale, acoustic rhinometry (AR), and peak nasal inspiratory flow (PF) were measured before and after the use of CPAP. RESULTS: There was an increase in nasal obstruction scores both on the VAS (p < 0.05) and on the NOSE scale (p < 0.05), as well as a reduction in nasal cavity volume on AR (p < 0.05) and a decline in PF (p < 0.05). Subjects were stratified into 2 groups: with and without symptoms of allergic rhinitis. Nasal parameters were significantly worse in the rhinitis group, with higher nasal obstruction scores on the VAS (p = 0.001) and NOSE scale (p < 0.001) and decreased PF (p < 0.001). CONCLUSION: Acute exposure to positive pressure via CPAP is associated with subjective and objective reductions in nasal patency. In individuals with allergic nasal symptoms, deterioration is even more severe than in patients without these symptoms.

来源:Int Forum Allergy Rhinol,查看原文。版权归原作者所有。

引用

  1. Balsalobre L, Pezato R, Gasparini H, et al. Acute impact of continuous positive airway pressure on nasal patency. Int Forum Allergy Rhinol. 2017. PMID: 28544812. doi:10.1002/alr.21948

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。