声电联合言语处理:长期结果
本研究为纵向单受试者设计,纳入50例接受Nucleus Hybrid短电极人工耳蜗植入者,术后随访至少2年(最长15年)。结果显示83%的S8组、92%的S12组和86%的L24组维持功能性听力纯音平均阈(125-500 Hz);纯音平均阈在术后0.5年内线性下降,之后稳定;CNC和AzBio句子得分在术后0.25至0.5年显著提高并达到最大。结论认为短电极人工耳蜗可长期维持声电联合处理听力和安静及噪声下的言语理解改善。
要点
- 短电极人工耳蜗植入后,多数患者可长期维持功能性听力(125-500 Hz纯音平均阈)。
- 术后0.5年内纯音平均阈线性下降,之后趋于稳定。
- 言语识别得分在术后0.25至0.5年显著提高并达到最大。
核心结论
- 长期研究表明,短电极人工耳蜗可长期维持声电联合处理听力和安静及噪声下的言语理解改善。
研究设计与样本
- 纵向、单受试者设计;纳入50例接受Nucleus Hybrid短电极人工耳蜗植入且术后纵向随访至少2年(最长15年)的受试者。
主要发现
- 纵向随访中,83%的S8组、92%的S12组和86%的L24组维持功能性听力纯音平均阈(125-500 Hz)。
- 分段线性混合模型预测的纯音平均阈随时间变化显示,每组术后听力线性下降直至0.5年,之后纯音平均阈稳定并维持。
- CNC和AzBio句子的个体数据平均显示,植入后0.25至0.5年得分显著改善,之后得分达到最大。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Few studies have investigated the stability of residual hearing and speech perception outcomes in individuals who were implanted with a shorter electrode device. STUDY DESIGN: Longitudinal, single-subject design. METHODS: Fifty subjects who received a Nucleus Hybrid (Cochlear, Sydney, Australia) short electrode cochlear implant (CI) and had a minimum of 2 years (and up to 15 years) of postoperative longitudinal experience were included in this study. Twenty-three subjects received a Nucleus Hybrid S8 (S8); 14 subjects received a Nucleus Hybrid L24 (L24); and 13 received a Nucleus Hybrid S12 (S12). Audiometric thresholds and consonant-nucleus-consonant (CNC) words were collected pre- and postoperatively for up to 15 years for the S8 subjects and for up to 7 years for the S12 and L24 subjects. AzBio Sentences in multi-talker babble was collected for up to 7 years on the S12 and L24 subjects. RESULTS: Longitudinally, 83% of the S8 subjects, 92% of the S12 subjects, and 86% of the L24 subjects maintained a functional hearing pure-tone average (PTA) (125-500 Hz). Predicted change using a piecewise linear mixed model in PTA over time showed a postoperative linear decrease in hearing for each group until 0.5 years, after which the PTA stabilizes and is maintained. The averaged individual data for CNC and AzBio sentences show a significant improvement in scores by 0.25 to 0.5 years postimplantation, after which scores start to reach their maximum. CONCLUSION: This long-term study demonstrates that acoustic-electric processing hearing and improvement in speech understanding in quiet and in noise can be accomplished and sustained for many years with a short electrode CI. LEVEL OF EVIDENCE: 2C. Laryngoscope, 128:473-481, 2018.
引用
- Gantz BJ, Dunn CC, Oleson J, et al. Acoustic plus electric speech processing: Long-term results. Laryngoscope. 2017. PMID: 28543270. doi:10.1002/lary.26669
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。