重度听力损失者认知筛查测试:听力受损版蒙特利尔认知评估(HI-MoCA)的研发
研究开发了适用于重度听力受损者的HI-MoCA,将MoCA转化为限时PowerPoint视觉指令版本,并在60岁以上认知完好成人中评估。103名正常听力者HI-MoCA得分26.66 vs MoCA 27.14(P<0.05),但0.48分差事后敏感性分析无临床意义;49名重度听力受损者两次HI-MoCA得分26.18和26.49(P>0.05),重测系数0.66。结论认为HI-MoCA易于实施且可靠,该队列无需转换因子。
要点
- HI-MoCA将MoCA的言语指令转为限时PowerPoint视觉指令,适用于重度听力受损者。
- 正常听力组HI-MoCA 26.66 vs MoCA 27.14(P<0.05),但0.48分差事后分析无临床意义。
- 重度听力受损组两次HI-MoCA 26.18和26.49(P>0.05),重测系数0.66。
核心结论
- HI-MoCA易于实施,用于重度听力受损者认知障碍筛查可靠。
- 在本文前瞻性测试的认知完好受试者队列中,无需转换因子。
研究设计与样本
- 测试开发后前瞻性招募受试者,招募60岁以上成人两组。
- 第一组为正常听力(组1),第二组为重度听力受损(组2)。
- 组1在T1接受MoCA或HI-MoCA,6个月后(T2)接受先前未做的另一测试以确定等效性。
- 组2在T1和T2均接受HI-MoCA以确定重测信度。
- 所有受试者通过筛查问卷排除未诊断的轻度认知障碍。
主要发现
- 组1招募103名受试者,HI-MoCA得分26.66 vs MoCA得分27.14,差异显著(P<0.05)。
- 组1中0.48分差经事后敏感性分析认为无临床意义。
- 组2招募49名受试者,HI-MoCA在T1和T2得分分别为26.18和26.49,无显著性(P>0.05)。
- 组2重测系数为0.66。
关键数值与推荐
- 组1:HI-MoCA得分26.66 vs MoCA得分27.14(P<0.05),0.48分差事后敏感性分析无临床意义。
- 组2:HI-MoCA在T1得分26.18,T2得分26.49(P>0.05),重测系数0.66。
临床怎么用
- HI-MoCA易于实施,可用于重度听力受损者的认知障碍筛查。
- 在本文前瞻性测试的认知完好受试者队列中,无需转换因子。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To develop a version of the Montreal Cognitive Assessment (MoCA) to be administered to the severely hearing impaired (HI-MoCA), and to assess its performance in two groups of cognitively intact adults over the age of 60. STUDY TYPE: Test development followed by prospective subject recruitment. METHODS: The MoCA was converted into a timed PowerPoint (Microsoft Corp., Redmond, WA) presentation, and verbal instructions were converted into visual instructions. Two groups of subjects over the age of 60 were recruited. All subjects passed screening questionnaires to eliminate those with undiagnosed mild cognitive impairment. The first group had normal hearing (group 1). The second group was severely hearing impaired (group 2). Group 1 received either the MoCA or HI-MoCA test (T1). Six months later (T2), subjects were administered the test (MoCA or HI-MoCA) they had not received previously to determine equivalency. Group 2 received the HI-MoCA at T1 and again at T2 to determine test-retest reliability. RESULTS: One hundred and three subjects were recruited into group 1, with a score of 26.66 (HI-MoCA) versus 27.14 (MoCA). This was significant (P < 0.05), but scoring uses whole numerals and the 0.48 difference was found not clinically significant using post hoc sensitivity analyses. Forty-nine subjects were recruited into group 2. They scored 26.18 and 26.49 (HI-MoCA at T1 and T2). No significance was noted (P > 0.05), with a test-retest coefficient of 0.66. CONCLUSION: The HI-MoCA is easy to administer and reliable for screening cognitive impairment in the severely hearing impaired. No conversion factor is required in our prospectively tested cohort of cognitively intact subjects. LEVEL OF EVIDENCE: 1b. Laryngoscope, 127:S4-S11, 2017.