文献速递耳科与耳神经

不同瞬态诱发耳声发射刺激条件下感音神经性听力损失的评估

Assessing Sensorineural Hearing Loss Using Various Transient-Evoked Otoacoustic Emission Stimulus Conditions.
PubMed 文献 · Ear Hear · 2017-01-01

研究纳入87名成人(正常听力40例,感音神经性听力损失47例),比较环境压力下未加权刺激、鼓室压峰压下未加权刺激及环境压力下功率加权刺激三种瞬态诱发耳声发射(TEOAE)条件在0.79至8 kHz的分类性能。结果显示三种条件的TEOAE在1至8 kHz基于信噪比和相干同步测量均表现良好,功率加权TEOAE在2和2.8 kHz性能最佳。

要点

  • 三种TEOAE刺激条件下正常听力耳平均信噪比≥8.7 dB,感音神经性听力损失耳≤6 dB。
  • 所有频率重测信度≤4.3 dB,1至4 kHz较低频率≤3.5 dB。
  • 除个别频率外,三种条件AUC在0.85至0.94之间,功率加权在2和2.8 kHz显著更高。

核心结论

  • 环境压力、鼓室压峰压及功率加权刺激条件下的TEOAE在1至8 kHz基于信噪比和相干同步测量对识别感音神经性听力损失具有良好测试性能及重测信度。
  • 功率加权TEOAE在2和2.8 kHz表现出最佳测试性能。
  • 这些发现作为识别耳蜗性听力损失的潜在客观临床工具令人鼓舞。

研究设计与样本

  • 研究纳入87名成人参与者,正常听力组40例(男16例,女24例,平均年龄30岁),感音神经性听力损失组47例(男20例,女27例,平均年龄58岁)。
  • 所有参与者符合226 Hz鼓室压测量标准临床标准的正常中耳功能。
  • 完成临床听力学、导抗及实验性宽带测试组合(包括反射和TEOAE测试,呈现时长1分钟),所有测试在1至2个月后重复。

主要发现

  • 三种刺激条件下所有频率正常听力耳平均TEOAE信噪比≥8.7 dB,感音神经性听力损失耳≤6 dB。
  • 两组所有频率平均重测信度≤4.3 dB,1至4 kHz较低频率通常≤3.5 dB。
  • 所有三种TEOAE条件在所有频率AUC在0.85至0.94之间,除外环境TEOAE条件2 kHz为0.82及所有条件5.7 kHz为0.78至0.81。
  • 以相干同步测量为分类变量时,功率加权TEOAE在2和2.8 kHz的AUC显著高于环境TEOAE(p < 0.05),鼓室压峰压TEOAE在2.8 kHz的AUC亦显著更高。

关键数值与推荐

  • TEOAE信噪比在0.79至8 kHz频率范围测量,分析1至8 kHz半倍频程平均信噪比和相干同步测量。
  • AUC在1至8 kHz听力学频率测量以区分感音神经性听力损失与正常听力。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: An important clinical application of transient-evoked otoacoustic emissions (TEOAEs) is to evaluate cochlear outer hair cell function for the purpose of detecting sensorineural hearing loss (SNHL). Double-evoked TEOAEs were measured using a chirp stimulus, in which the stimuli had an extended frequency range compared to clinical tests. The present study compared TEOAEs recorded using an unweighted stimulus presented at either ambient pressure or tympanometric peak pressure (TPP) in the ear canal and TEOAEs recorded using a power-weighted stimulus at ambient pressure. The unweighted stimulus had approximately constant incident pressure magnitude across frequency, and the power-weighted stimulus had approximately constant absorbed sound power across frequency. The objective of this study was to compare TEOAEs from 0.79 to 8 kHz using these three stimulus conditions in adults to assess test performance in classifying ears as having either normal hearing or SNHL. DESIGN: Measurements were completed on 87 adult participants. Eligible participants had either normal hearing (N = 40; M F = 16 24; mean age = 30 years) or SNHL (N = 47; M F = 20 27; mean age = 58 years), and normal middle ear function as defined by standard clinical criteria for 226-Hz tympanometry. Clinical audiometry, immittance, and an experimental wideband test battery, which included reflectance and TEOAE tests presented for 1-min durations, were completed for each ear on all participants. All tests were then repeated 1 to 2 months later. TEOAEs were measured by presenting the stimulus in the three stimulus conditions. TEOAE data were analyzed in each hearing group in terms of the half-octave-averaged signal to noise ratio (SNR) and the coherence synchrony measure (CSM) at frequencies between 1 and 8 kHz. The test-retest reliability of these measures was calculated. The area under the receiver operating characteristic curve (AUC) was measured at audiometric frequencies between 1 and 8 kHz to determine TEOAE test performance in distinguishing SNHL from normal hearing. RESULTS: Mean TEOAE SNR was ≥8.7 dB for normal-hearing ears and ≤6 dB for SNHL ears for all three stimulus conditions across all frequencies. Mean test-retest reliability of TEOAE SNR was ≤4.3 dB for both hearing groups across all frequencies, although it was generally less (≤3.5 dB) for lower frequencies (1 to 4 kHz). AUCs were between 0.85 and 0.94 for all three TEOAE conditions at all frequencies, except for the ambient TEOAE condition at 2 kHz (0.82) and for all TEOAE conditions at 5.7 kHz with AUCs between 0.78 and 0.81. Power-weighted TEOAE AUCs were significantly higher (p < 0.05) than ambient TEOAE AUCs at 2 and 2.8 kHz, as was the TPP TEOAE AUC at 2.8 kHz when using CSM as the classifier variable. CONCLUSIONS: TEOAEs evaluated in an ambient condition, at TPP and in a power-weighted stimulus condition, had good test performance in identifying ears with SNHL based on SNR and CSM in the frequency range from 1 to 8 kHz and showed good test-retest reliability. Power-weighted TEOAEs showed the best test performance at 2 and 2.8 kHz. These findings are encouraging as a potential objective clinical tool to identify patients with cochlear hearing loss.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Putterman DB, Keefe DH, Hunter LL, et al. Assessing Sensorineural Hearing Loss Using Various Transient-Evoked Otoacoustic Emission Stimulus Conditions. Ear Hear. 2017. PMID: 28437273. doi:10.1097/AUD.0000000000000425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。