预弯人工耳蜗电极阵列患者定制置入技术的回顾性评估
本研究回顾性分析97例人工耳蜗植入耳,利用CT和自动图像分析量化预弯电极阵列的蜗轴周围距离,平均为0.59±0.18 mm。实际与推荐置入深度之间的不一致与蜗轴周围距离呈正相关(r=0.49,P<0.0001)。结果表明许多电极远离蜗轴,作者提出的患者定制置入深度方法可能改善蜗轴周围放置。
要点
- 预弯电极阵列平均蜗轴周围距离为0.59±0.18 mm。
- 实际与推荐置入深度不一致与蜗轴周围距离正相关(r=0.49,P<0.0001)。
- 作者提出的患者定制置入深度方法可能改善蜗轴周围放置。
核心结论
- 平均而言,使用预弯电极阵列的人工耳蜗植入者存在多个电极远离蜗轴,未处于最有效位置。
- 作者提出的患者定制电极阵列置入深度选择方法可能导致更好的蜗轴周围放置。
研究设计与样本
- 回顾性病历审查和影像学分析。
- 单中心三级学术转诊中心。
- 评估97例人工耳蜗植入耳。
主要发现
- 平均蜗轴周围距离为0.59±0.18 mm。
- 实际置入深度与推荐置入深度之间的不一致与蜗轴周围距离呈正相关(r=0.49,P<.0001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective Precurved electrode arrays (EAs) are commonly used in cochlear implants (CIs). Modiolar placement of such arrays has been shown to lead to better hearing outcomes. In this project, we retrospectively evaluated the modiolar positioning of EAs within a large CI imaging database. We aimed to discover the rate at which perimodiolar placement is successfully achieved and to evaluate a new technique we propose to preoperatively plan patient-customized EA insertion depths to improve perimodiolar placement at the time of surgery. Study Design Retrospective chart review and radiographic analysis. Setting Single tertiary academic referral center. Subjects and Methods Ninety-seven CI ears were evaluated. Perimodiolar positioning of electrodes was quantified using pre- and postimplantation computed tomography scans and automated image analysis techniques. Results Average perimodiolar distance was 0.59 ± 0.18 mm. Disagreement between the actual and our recommended insertion depth was found to be positively correlated with perimodiolar distance ( r = 0.49, P < .0001). Conclusions These results show that the average CI recipient with a precurved EA has a number of electrodes distant to the modiolus where they are not most effective. Our results also indicate the approach we propose for selecting patient-customized EA insertion depth would lead to better perimodiolar placement of precurved EAs.
引用
- Wang J, Dawant BM, Labadie RF, et al. Retrospective Evaluation of a Technique for Patient-Customized Placement of Precurved Cochlear Implant Electrode Arrays. Otolaryngol Head Neck Surg. 2017. PMID: 28374623. doi:10.1177/0194599817697298
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。