文献速递睡眠呼吸障碍咽喉与嗓音

药物诱导睡眠内镜联合在线多导心肺监测的技术与初步分析

Technique and Preliminary Analysis of Drug-Induced Sleep Endoscopy With Online Polygraphic Cardiorespiratory Monitoring in Patients With Obstructive Sleep Apnea Syndrome.
PubMed 文献 · JAMA Otolaryngol Head Neck Surg · 2017-01-01

这项前瞻性队列研究纳入50例阻塞性睡眠呼吸暂停综合征患者,于2013年3月1日至2014年6月30日接受药物诱导睡眠内镜联合同步多导心肺参数监测(DISE-PG)。结果显示该技术可行、安全,多导监测识别阻塞事件的敏感性高于单纯内镜评分(平均总事件13.3 vs 5.3)。作者认为DISE-PG有助于准确理解上气道阻塞动力学及非阻塞性呼吸模式。

要点

  • 50例患者均顺利完成DISE-PG,无技术问题或患者困难。
  • 多导评分较内镜评分识别更多阻塞事件(平均13.3 vs 5.3)。
  • 基线AHI较高或低通气占比较高者,两种评分差异更明显。

核心结论

  • DISE-PG技术可行、安全,检测阻塞性呼吸模式的敏感性高于单纯药物诱导睡眠内镜。
  • DISE-PG有助于准确理解上气道阻塞动力学(阻塞程度和多平面模式)及非阻塞性呼吸模式(如中枢性呼吸暂停)。

研究设计与样本

  • 前瞻性队列研究,纳入2013年3月1日至2014年6月30日连续50例阻塞性睡眠呼吸暂停综合征患者。
  • 所有操作由经验丰富的耳鼻咽喉科医生在麻醉科医生监督下于手术室完成,采用标准方案。
  • 内镜与多导阻塞性呼吸事件在双盲、随机顺序下离线分析。

主要发现

  • 全部50例患者(43男、7女;平均[SD]年龄51.1[12.1]岁)接受DISE-PG,无技术问题或患者困难。
  • 多导评分识别阻塞事件的平均[SD]总事件数为13.3[6.8],内镜评分为5.3[3.6];平均[SD]差值为8.8[5.6](95%CI 7.3至10.4;Cohen d -1.5)。
  • 基线AHI>30者平均[SD]差异为27.1%[31.0%](95%CI -36.2%至90.4%;Cohen d 0.2);AHI>40者为76.0%[35.5%](95%CI 4.6%至147.4%;Cohen d 0.5);AHI>50者为92.2%[37.2%](95%CI 17.3%至167.1%;Cohen d 0.6)。
  • 基线低通气占所有阻塞事件≥75%者平均[SD]差异为20.2%[5.4%](95%CI 9.2%至31.3%;Cohen d 1.1)。
  • 其他基线人体测量或多导特征与DISE-PG和基线家庭睡眠呼吸暂停检测之间的差异无关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Drug-induced sleep endoscopy is a diagnostic technique that allows dynamic evaluation of the upper airway during artificial sleep. The lack of a standardized procedure and the difficulties associated with direct visual detection of obstructive events result in poor intraobserver and interobserver reliability, especially when otolaryngology surgeons not experienced in the technique are involved. OBJECTIVES: To describe a drug-induced sleep endoscopy technique implemented with simultaneous polygraphic monitoring of cardiorespiratory parameters (DISE-PG) in patients with a diagnosis of obstructive sleep apnea syndrome and discuss the technique's possible advantages compared with the standard procedure. DESIGN, SETTING, AND PARTICIPANTS: This prospective cohort study included 50 consecutive patients with obstructive sleep apnea syndrome who underwent DISE-PG from March 1, 2013, to June 30, 2014. A standard protocol was adopted, and all the procedures were carried out in an operation room by an experienced otolaryngology surgeon under the supervision of an anesthesiologist. Endoscopic and polygraphic obstructive respiratory events were analyzed offline in a double-blind setting and randomized order. MAIN OUTCOMES AND MEASURES: The feasibility and safety of the DISE-PG technique, as well as its sensitivity in detecting respiratory events compared with that of the standard drug-induced sleep endoscopy procedure. RESULTS: All 50 patients (43 men and 7 women; mean [SD] age, 51.1 [12.1] years) underwent DISE-PG without technical problems or patient difficulties regarding the procedure. As expected, polygraphic scoring was more sensitive than endoscopic scoring in identifying obstructive events (mean [SD] total events, 13.3 [6.8] vs 5.3 [3.6]; mean [SD] difference, 8.8 [5.6]; 95% CI, 7.3 to 10.4; Cohen d, -1.5). This difference was most pronounced in patients with a higher apnea-hypopnea index (AHI) at baseline (mean [SD] difference for AHI >30, 27.1% [31.0%]; 95% CI, -36.2% to 90.4%; Cohen d, 0.2; for AH I >40, 76.0% [35.5%]; 95% CI, 4.6% to 147.4%; Cohen d, 0.5; for AHI >50, 92.2% [37.2%]; 95% CI, 17.3% to 167.1%; Cohen d, 0.6) and a high percentage of hypopneas (≥75% of all obstructive events) at baseline (mean [SD] difference, 20.2% [5.4%]; 95% CI, 9.2% to 31.3%; Cohen d, 1.1). No other anthropomorphic or polygraphic features at baseline were associated with the differences between the DISE-PG and baseline home sleep apnea test. CONCLUSIONS AND RELEVANCE: The DISE-PG technique is feasible, safe, and more sensitive at detecting an obstructed breathing pattern than is drug-induced sleep endoscopy alone. The DISE-PG technique could be helpful for accurate comprehension of upper airway obstructive dynamics (ie, degree of obstruction and multilevel pattern) and a nonobstructive breathing pattern (ie, central apneas).

来源:JAMA Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Gobbi R, Baiardi S, Mondini S, et al. Technique and Preliminary Analysis of Drug-Induced Sleep Endoscopy With Online Polygraphic Cardiorespiratory Monitoring in Patients With Obstructive Sleep Apnea Syndrome. JAMA Otolaryngol Head Neck Surg. 2017. PMID: 28253389. doi:10.1001/jamaoto.2016.3964

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。