文献速递咽喉与嗓音

视频荧光吞咽检查的主观评估

Subjective Assessment of Videofluoroscopic Swallow Studies.
PubMed 文献 · Otolaryngol Head Neck Surg · 2017-02-14

该双盲实验将76例吞咽障碍患者的视频荧光吞咽检查(VFSS)去标识视频分别呈现给经验丰富的言语语言病理学家和喉科医生,评估其对舌骨抬高、咽面积、咽收缩比和咽食管段开放的主观判读准确性。评估者仅正确分类61.5%的视频,评估者间一致性中等(κ=0.48),各参数准确率45.3%至71.6%,结论认为主观评估与客观测量相比准确性不一致。

要点

  • 评估者仅正确分类61.5%的VFSS视频,评估者间一致性中等(κ=0.48)。
  • 咽收缩比准确率最高(71.6%),咽面积最低(45.3%)。
  • 评估者一致正确判读同一VFSS视频的比例仅为28%。

核心结论

  • 与客观测量相比,VFSS参数的主观评估准确性不一致,各参数准确率为45.3%至71.6%。
  • 主观评估的评估者间和评估者内信度为中等且高度可变。

研究设计与样本

  • 双盲实验,共纳入76例吞咽障碍患者VFSS评估的去标识视频。
  • 视频分别呈现给盲法的经验丰富的言语语言病理学家和喉科医生进行独立评估。

主要发现

  • 评估者正确分类VFSS视频为正常或异常的比例仅为61.5%,评估者间一致性中等(κ=0.48,P<.0001)。
  • 评估者内一致性高度可变(κ=0.43-0.83)。
  • 各参数准确率:咽收缩比71.6%,舌骨抬高61.3%,咽食管段开放59.2%,咽面积45.3%。
  • 评估者间一致性:咽收缩比κ=0.59,咽食管段开放κ=0.54,咽面积κ=0.44,舌骨抬高κ=0.40。
  • 评估者对同一VFSS视频一致正确判读的比例为28%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective The videofluoroscopic swallow study (VFSS) is the gold standard diagnostic tool to evaluate oropharyngeal dysphagia. Although objective measurements on VFSS have been described, there is no universal method of analysis, and the majority of clinicians use subjective interpretation alone. The purpose of this investigation was to evaluate the accuracy of subjective VFSS analysis. Study Design Double-blinded experiment. Setting Tertiary care laryngology center. Subjects and Methods Seventy-six de-identified videos from VFSS evaluations of patients with dysphagia were presented to blinded, experienced speech-language pathologists and laryngologists individually. Evaluators rated each video as normal or abnormal for hyoid elevation (HE), pharyngeal area (PA), pharyngeal constriction ratio (PCR), and pharyngoesophageal segment opening (PESo). A blinded investigator assessed evaluators' inter- and intrarater agreement and compared their responses to objectively measured results for these parameters to examine accuracy. Results Evaluators correctly classified only 61.5% of VFSS videos as normal or abnormal, with moderate interrater agreement (κ = 0.48, P < .0001). Intrarater agreement was highly variable (κ = 0.43-0.83). Accuracy was greatest for PCR (71.6%), with poorer performance for HE (61.3%), PESo (59.2%), and PA (45.3%). Interrater agreement was moderate for all parameters, with greater concordance for PCR (κ = 0.59) and PESo (κ = 0.54) and less for HE (κ = 0.40) and PA (κ = 0.44). Evaluators unanimously agreed on a correct interpretation of a VFSS only 28% of the time. Conclusion Subjective assessment of VFSS parameters is inconsistently accurate when compared with objective measurements, with accuracy ratings ranging from 45.3% to 71.6% for specific parameters. Inter- and intrarater reliability for subjective assessment was moderate and highly variable.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Lee JW, Randall DR, Evangelista LM, et al. Subjective Assessment of Videofluoroscopic Swallow Studies. Otolaryngol Head Neck Surg. 2017. PMID: 28195753. doi:10.1177/0194599817691276

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。