窄带成像对喉癌的诊断性能:系统评价与Meta分析
该系统评价与Meta分析纳入6项研究、共716处病变,评估窄带成像(NBI)诊断喉癌的性能并与白光内镜比较。NBI合并敏感度0.94、特异度0.89、诊断比值比142.12;3项研究评价白光内镜,敏感度0.81、特异度0.92、诊断比值比33.82。作者认为NBI敏感度优于白光内镜,其潜在价值需在未来研究中验证。
要点
- NBI诊断喉癌合并敏感度0.94(95%CI 0.91-0.96),特异度0.89(95%CI 0.85-0.92)。
- 3项研究白光内镜敏感度0.81(95%CI 0.76-0.86),特异度0.92(95%CI 0.88-0.95)。
- 作者认为NBI敏感度优于白光内镜,其潜在价值需在未来研究中验证。
核心结论
- NBI诊断喉癌的敏感度优于白光内镜,NBI的潜在价值需在未来研究中验证。
研究设计与样本
- 系统评价与Meta分析,检索PubMed、Embase、Cochrane Library和CNKI数据库,纳入6项研究共716处病变。
- 采用Meta-DiSc软件分析,使用更新的QUADAS-2工具评估研究质量与潜在偏倚,采用Deeks不对称检验评估发表偏倚。
- 研究方案已在PROSPERO注册(注册号CRD42015025866),并遵循PRISMA清单。
主要发现
- NBI诊断喉癌的合并敏感度为0.94(95%CI 0.91-0.96),合并特异度为0.89(95%CI 0.85-0.92),诊断比值比为142.12(95%CI 46.42-435.15),受试者工作特征曲线下面积为0.97。
- 6项研究中有3项评价白光内镜,其敏感度为0.81(95%CI 0.76-0.86),特异度为0.92(95%CI 0.88-0.95),诊断比值比为33.82(95%CI 14.76-77.49)。
- 按诊断比值比计算的异质性I2为66%。
- 未发现明显发表偏倚(P = .84)。
关键数值与推荐
- NBI诊断喉癌:合并敏感度0.94(95%CI 0.91-0.96)、特异度0.89(95%CI 0.85-0.92)、诊断比值比142.12(95%CI 46.42-435.15)、曲线下面积0.97。
- 白光内镜诊断喉癌(3项研究):敏感度0.81(95%CI 0.76-0.86)、特异度0.92(95%CI 0.88-0.95)、诊断比值比33.82(95%CI 14.76-77.49)。
- 异质性按诊断比值比计算I2为66%;发表偏倚检验P = .84。
临床怎么用
- 原文未据此给出推荐。
局限性
- 按诊断比值比计算的异质性I2为66%。
- NBI的潜在价值需在未来研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective To evaluate the performance of narrow band imaging (NBI) for the diagnosis of laryngeal cancer and to compare the diagnostic value of NBI with that of white light endoscopy. Data Sources PubMed, Embase, Cochrane Library, and CNKI databases. Review Methods Data analyses were performed with Meta-DiSc. The updated Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality and potential bias. Publication bias was assessed with the Deeks's asymmetry test. The protocol used in this article has been published on PROSPERO and is in accordance with the PRISMA checklist. The registry number for this study is CRD42015025866. Results Six studies including 716 lesions were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio for the NBI diagnosis of laryngeal cancer were 0.94 (95% confidence interval [95% CI]: 0.91-0.96), 0.89 (95% CI: 0.85-0.92), and 142.12 (95% CI: 46.42-435.15), respectively, and the area under receiver operating characteristics curve was 0.97. Among the 6 studies, 3 evaluated the diagnostic value of white light endoscopy, with a sensitivity of 0.81 (95% CI: 0.76-0.86), a specificity of 0.92 (95% CI: 0.88-0.95), and a diagnostic odds ratio of 33.82 (95% CI: 14.76-77.49). The evaluation of heterogeneity, calculated per the diagnostic odds ratio, gave an I2 of 66%. No marked publication bias ( P = .84) was detected in this meta-analysis. Conclusion The sensitivity of NBI is superior to white light endoscopy, and the potential value of NBI needs to be validated in future studies.