文献速递耳科与耳神经

人工耳蜗电极阵列对中耳传递函数的影响

The Impact of a Cochlear Implant Electrode Array on the Middle Ear Transfer Function.
PubMed 文献 · Ear Hear · 2017-01-01

研究在六块未固定人颞骨上测量声音诱导的卵圆窗与圆窗净体积速度,比较蜗窗造孔与圆窗插入四种电极阵列后的中耳传递函数。结果显示插入后中耳传递函数及两窗体积速度比的变化几乎均无统计学意义,电极阵列类型与插入路径对变化似无影响。

要点

  • 在六块人颞骨上,电极插入后卵圆窗与圆窗体积速度变化无系统性趋势。
  • 中耳传递函数及卵圆窗与圆窗体积速度比的变化几乎均无统计学意义。
  • 作者认为电极阵列插入后不显著增加耳蜗输入阻抗,变化似与电极类型和插入路径无关。

核心结论

  • 耳蜗内电极阵列在插入后不显著增加耳蜗输入阻抗,出现的变化似乎与电极阵列类型和插入路径无关。

研究设计与样本

  • 在六块未固定人颞骨上,用激光测振仪测量声音诱导的卵圆窗与圆窗净体积速度。
  • 先做自然状态基线测量,再钻蜗窗造孔并用结缔组织封闭,经造孔插入四种不同电极阵列。
  • 随后经圆窗插入电极阵列,同时再次用结缔组织修补蜗窗造孔。

主要发现

  • 钻蜗窗造孔并插入电极后,卵圆窗与圆窗体积速度变化未观察到系统性趋势。
  • 中耳传递函数以及卵圆窗与圆窗体积速度比的变化几乎均无统计学意义。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: As a treatment for partial deafness with residual hearing in the lower frequency range, the combined acoustic and electric stimulation of the cochlea has become widespread. Acoustic stimulation is provided by a hearing aid's airborne sound and the electric stimulation by a cochlear implant electrode array, which may be inserted through the round window or a cochleostomy. To take advantage of that concept, it is essential to preserve residual hearing after surgery. Therefore, the intracochlear electrode array should not compromise the middle ear vibration transmission. This study investigates the influence of different electrode types and insertion paths on the middle ear transfer function and the inner ear fluid dynamics. DESIGN: Sound-induced oval and round window net volume velocities were calculated from vibration measurements with laser vibrometers on six nonfixated human temporal bones. After baseline measurements in the "natural" condition, a cochleostomy was drilled and closed with connective tissue. Then, four different electrode arrays were inserted through the cochleostomy. Afterwards, they were inserted through the round window while the cochleostomy was patched again with connective tissue. RESULTS: After having drilled a cochleostomy and electrode insertion, no systematic trends in the changes of oval and round window volume velocities were observed. Nearly all changes of middle ear transfer functions, as well as oval and round window volume velocity ratios, were statistically insignificant. CONCLUSIONS: Intracochlear electrode arrays do not significantly increase cochlear input impedance immediately after insertion. Any changes that may occur seem to be independent of electrode array type and insertion path.

来源:Ear Hear,查看原文。版权归原作者所有。