文献速递耳科与耳神经

序贯双侧人工耳蜗植入后的生活质量评估

Quality of Life after Sequential Bilateral Cochlear Implantation.
PubMed 文献 · Otolaryngol Head Neck Surg · 2016-10-25

本研究在学术人工耳蜗中心前瞻性评估综合人工耳蜗问卷(CCIQ)的心理测量学特性,共56例患者中32例(57.1%)完成邮寄问卷,其中22例(68.8%)在6周后完成重测。CCIQ各领域显示健康相关生活质量(HRQoL)显著提高,内部一致性很好(Cronbach's α=0.90),重测信度良好(总体组内相关系数0.62),且与Nijmegen人工耳蜗问卷呈中度相关、与SF-12呈低相关。平均CNC和AzBio评分分别显著提高31%±29%和34%±33%,听力测量数据与CCIQ无显著相关。

要点

  • CCIQ各领域显示第二侧人工耳蜗植入后HRQoL显著提高。
  • CCIQ内部一致性很好(Cronbach's α=0.90),重测信度良好(组内相关系数0.62)。
  • 平均CNC和AzBio评分分别显著提高31%±29%和34%±33%。

核心结论

  • CCIQ显示出良好的信度和结构效度证据,第二侧人工耳蜗植入后HRQoL显著提高且言语感知显著改善,检测HRQoL改善的敏感性更高。

研究设计与样本

  • 前瞻性研究,在学术人工耳蜗中心进行,56例患者中32例(57.1%)完成邮寄的问卷工具。

主要发现

  • 32例患者中22例(68.8%)在6周后完成CCIQ重测。
  • CCIQ各领域显示HRQoL显著提高,内部一致性总体很好(Cronbach's α=0.90),所有子领域α值均超过0.70。
  • 重测信度良好,总体组内相关系数为0.62。
  • CCIQ与Nijmegen人工耳蜗问卷呈中度相关,与SF-12呈低相关。
  • 平均CNC和AzBio评分分别显著提高31%±29%和34%±33%,听力测量数据与CCIQ无显著相关。

关键数值与推荐

  • CCIQ为29条目问卷,基于5点Likert量表评估第二侧人工耳蜗植入的躯体和社会心理获益。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective Assess psychometric properties of the Comprehensive Cochlear Implant Questionnaire (CCIQ) as a tool for assessing changes in health-related quality of life (HRQoL) after receiving a second cochlear implant (CI2). Study Design Prospective study. Setting Academic cochlear implant center. Subjects and Methods The CCIQ is a 29-item questionnaire assessing the physical and psychosocial benefits of a CI2 based on a 5-point Likert scale. The CCIQ was administered with the Nijmegen Cochlear Implant Questionnaire and the Short Form-12 Patient Questionnaire (SF-12) to patients with a CI2. Speech perception was tested with the consonant-nucleus-consonant (CNC) word test and AzBio test. Results Of 56 patients, 32 (57.1%) completed the instruments sent by mail. Of the 32 patients, 22 (68.8%) completed retest CCIQs 6 weeks later. CCIQ scores demonstrated significantly increased HRQoL in all domains. Internal consistency was very good overall (Cronbach's α = 0.90), with all subdomains exceeding an alpha value of 0.70. Test-retest reliability was good, with an overall intraclass correlation of 0.62. The CCIQ showed a moderate correlation with the Nijmegen Cochlear Implant Questionnaire and a low correlation with the SF-12. Average CNC and AZBio scores significantly improved by 31% ± 29% and 34% ± 33%, respectively. Audiometric data were not significantly correlated with the CCIQ. Conclusion The CCIQ shows (1) good reliability and evidence of construct validity, (2) a significant increase in HRQoL and significantly improved speech perception after CI2, and (3) greater sensitivity at detecting CI2 improvements to HRQoL. This promising measure is quick and easy to administer and provides subjective assessments of HRQoL specifically for those with a CI2.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Nahm EA, Liberatos P, Shi Q, et al. Quality of Life after Sequential Bilateral Cochlear Implantation. Otolaryngol Head Neck Surg. 2016. PMID: 28145846. doi:10.1177/0194599816674685

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。