利用畸变产物耳声发射估计人类轻度传导性听力损失

Estimation of Minor Conductive Hearing Loss in Humans Using Distortion Product Otoacoustic Emissions.
PubMed 文献 · Ear Hear · 2017-01-01

研究纳入30名听力正常成人的单耳,通过改变耳道压力(0 daPa与足以使阈值升高3至10 dB的负压)制造轻度传导性听力损失(CHL),比较纯音测听法与畸变产物耳声发射(DPOAE)法对CHL的估计。结果显示两种估计值呈高度显著线性相关(r(19)=0.71,p<0.001),但仅在使用耳特异性优化公式参数时相关显著;使用通用非频率特异性参数时准确性显著降低。

要点

  • 纯音测听与DPOAE估计的CHL呈高度显著线性相关(r(19)=0.71,p<0.001)。
  • 该相关仅在已知耳特异性优化公式参数时显著。
  • 通用非频率特异性参数估计准确性显著低于耳特异性(p<0.001)或通用频率特异性参数(p=0.007)。

核心结论

  • 当已知某耳(伴或不伴轻度CHL)的优化公式参数时,CHLDP对CHLPT具有显著预测性;但使用通用初级音水平公式参数时缺乏有意义的关系,显著限制了该方法的临床实用性潜力。

研究设计与样本

  • 研究纳入30名听力正常成人的单耳,采用自动Békésy测听在0 daPa及足以使1 kHz纯音阈值升高3至10 dB的负压耳道压力下获取阈值。
  • 以两种耳道压力下阈值差定义纯音测听估计的CHL(CHLPT),并以f2=1 kHz识别最优DPOAE初级音水平关系,以两种压力条件下最优L1-L2关系之差定义ΔL1OPT。
  • DPOAE估计的CHL(CHLDP)通过公式CHLDP=ΔL1OPT/(1-a)获得,其中a为无CHL时观察到的最优L1-L2关系斜率。

主要发现

  • 纯音测听与DPOAE估计的CHL之间存在高度显著线性依赖,r(19)=0.71,p<0.001。
  • 该相关仅在已知耳特异性优化公式参数时显著。
  • 使用通用非频率特异性参数时,估计准确性显著低于耳特异性参数(p<0.001)和通用频率特异性参数(p=0.007)。

关键数值与推荐

  • DPOAE估计公式:CHLDP=ΔL1OPT/(1-a),其中a为无CHL时最优L1-L2关系斜率。
  • 初级音水平搜索范围:20≤L2≤70 dB SPL,L1在推荐值L1=0.49 L2+41(dB SPL)上下各变化15 dB。
  • 纯音测听阈值在1 kHz、耳道压力0 daPa及使阈值升高3至10 dB的负压下获取。

临床怎么用

  • 原文结论指出,使用通用初级音水平公式参数时缺乏有意义关系,显著限制了该方法临床实用性潜力。

局限性

  • 使用通用初级音水平公式参数时缺乏有意义关系,显著限制了该方法的临床实用性潜力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Conductive hearing loss (CHL) systematically alters distortion product otoacoustic emission (DPOAE) levels through attenuation of both the primary tones and the evoked response by the middle ear, as well as through modification of the effective L1-L2 relationship within the cochlea. It has been postulated that, if optimal primary tone level relationships for an ear without CHL are known or can be estimated accurately and a CHL can be presumed to attenuate both primary tones to a similar extent, the adjustment to L1 required to restore an optimal L1-L2 separation following CHL induction can be utilized to estimate CHL magnitude objectively. The primary aim of this study was to assess the feasibility of objectively estimating experimentally produced CHL in humans by comparing CHL estimates resulting from DPOAE- and pure-tone audiometry-based methods. A secondary aim was to compare the accuracy of DPOAE-based CHL estimates when obtained using generic, as opposed to ear-specific, optimal primary tone level formula parameters. DESIGN: For a single ear of 30 adults with normal hearing, auditory threshold for a 1 kHz tone was obtained using automated Békésy audiometry at an ear-canal pressure of 0 daPa, as well as at a negative pressure sufficient for increasing threshold by 3 to 10 dB. The difference in threshold for the ear-canal pressure conditions was defined as the pure-tone audiometry-based estimate of CHL (CHLPT). For the same two ear-canal pressures, optimal DPOAE primary tone level relationships were identified for f2 = 1 kHz. Specifically, for 20 ≤ L2 ≤ 70 dB SPL, L1 was varied 15 dB above and below the recommendation of L1 = 0.49 L2 + 41 (dB SPL). The difference between the optimal L1-L2 relationships for the two pressure conditions was defined as ΔL1OPT. A DPOAE-based estimate of CHL (CHLDP) was obtained using the formula CHLDP = ΔL1OPT/(1 - a), where a represents the slope of the optimal L1-L2 relationship observed in the absence of CHL. RESULTS: A highly significant linear dependence was identified between pure-tone audiometry- and DPOAE-based estimates of CHL, r(19) = 0.71, p < 0.001. However, the correlation was only significant when ear-specific optimization formula parameters were known. Use of generic, frequency-nonspecific parameters resulted in significantly less accurate estimates than did either ear-specific (p < 0.001) or generic, frequency-specific parameters (p = 0.007). CONCLUSIONS: This study provides empirical support for a theory of how CHL, through a combination of middle ear filtering and alteration of effective primary tone level relationships within the cochlea, systematically affects DPOAE amplitude. Although CHLDP was shown to be significantly predictive of CHLPT when optimization formula parameters for a given ear, both with and without mild CHL, were known, the lack of a meaningful relationship when using generic primary tone level formula parameters significantly limits the method's potential for clinical utility.