文献速递鼻科

鼻窦疾病诊疗中鼻窦CT成像效率不足的问题

Inefficiencies in Computed Tomography Sinus Imaging for Management of Sinonasal Disease.
PubMed 文献 · Otolaryngol Head Neck Surg · 2017-01-10

一项2012年5月至2013年8月在三级鼻科门诊开展的回顾性病历研究,纳入183例携带外院鼻窦CT的新发鼻窦疾病患者。85例(46%)的诊断性CT对图像引导鼻窦手术(IGSS)不充分,71例符合IGSS指征者中37例(52%)因诊断性CT不充分而需重复CT。作者认为标准化IGSS适用CT方案或可避免重复术前扫描。

要点

  • 183例携带外院鼻窦CT的患者中,85例(46%)的诊断性CT对IGSS不充分。
  • 71例符合IGSS指征的患者中,37例(52%)因诊断性CT不充分需重复CT。
  • 作者认为标准化IGSS适用CT方案或可避免重复术前扫描。

核心结论

  • 在开展IGSS的三级医疗中心,重复术前鼻窦CT成像的频率可能较高。
  • 标准化的IGSS适用鼻窦CT方案或可避免重复术前扫描,潜在优势包括提高效率、降低医疗费用和减少患者电离辐射暴露。

研究设计与样本

  • 回顾性病历研究,2012年5月至2013年8月在三级鼻科门诊开展。
  • 纳入183例携带外院鼻窦CT、具有任何鼻窦诊断的新发患者。

主要发现

  • 183例患者中,85例(46%)的诊断性鼻窦CT对IGSS不充分。
  • 71例符合IGSS指征的患者中,37例(52%)因诊断性CT对IGSS不充分而需重复CT。

关键数值与推荐

  • CT对IGSS不充分的判定标准包括:层厚大于1.5 mm、因机架倾斜导致轴位平面倾斜、IGSS解剖标志定义不完整或缺失。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Objective A subset of patients with sinonasal disease who obtain a diagnostic computed tomography (CT) sinus scan may require repeat preoperative CT due to the inadequacy of diagnostic CT for image-guided sinus surgery (IGSS). This leads to increased CT utilization, health care costs, and patient exposure to ionizing radiation. The objective of this study is to determine the frequencies of diagnostic CT sinus studies that were inadequate for IGSS and repeat CT studies for purposes of IGSS. Study Design A retrospective chart study was performed between May 2012 and August 2013. Setting Tertiary care rhinology practice. Subjects and Methods New patients with any sinonasal diagnosis who presented with CT sinus scans acquired from outside institutions were included. CT scans were considered inadequate for IGSS for any of the following reasons: >1.5-mm slice thickness, oblique axial planes due to gantry tilt, and incompletely defined or missing IGSS anatomic landmarks. Results Of 183 patients, 85 (46%) presented with diagnostic CT sinus scans that were inadequate for IGSS. Seventy-one patients met indications for IGSS, of which 37 (52%) required repeat CT due to an IGSS-inadequate diagnostic scan. Conclusion The frequency of repeat preoperative CT sinus imaging may be high at tertiary care centers where IGSS is performed. A standardized IGSS-adequate CT sinus protocol may avoid the need for repeat preoperative scans. Potential advantages include improved efficiency, decreased health care costs, and reduced ionizing radiation exposure to the patient.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Sharma GK, Foulad A, Shamouelian D, et al. Inefficiencies in Computed Tomography Sinus Imaging for Management of Sinonasal Disease. Otolaryngol Head Neck Surg. 2017. PMID: 28072563. doi:10.1177/0194599816685694

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。