文献速递耳科与耳神经

耳蜗损伤对谐和性敏感度的影响

The Effect of Cochlear Damage on the Sensitivity to Harmonicity.
PubMed 文献 · Ear Hear · 2017-01-01

研究纳入12名听力正常(NH)与8名耳蜗听力损失30至50 dB(平均42 dB,0.25至3 kHz)的受试者,用自适应强迫选择法测量同时呈现纯音频率比变化检测阈值。两组在标准频率比为谐和(2:1)时阈值均低于非谐和(0.8或1.2倍频程),但部分听力损失者对谐和性的敏感度减弱;NH组对负向偏离(压缩)检测优于正向偏离(拉伸),听力损失组偏离方向无影响。

要点

  • 标准频率比为谐和(2:1)时两组检测阈值均低于非谐和(0.8或1.2倍频程)。
  • 部分听力损失者对谐和性的敏感度减弱,但该效应在频率辨别能力很差者中仍可观察到。
  • NH组对负向偏离(压缩)检测优于正向偏离(拉伸),听力损失组偏离方向无影响。

核心结论

  • 谐和性敏感度似乎相当稳健,但在部分轻度或中度耳蜗损伤的听者中可能减弱。
  • 非谐和性检测在NH听者中呈不对称性,而在耳蜗损伤时似乎变为对称,耳蜗损伤听者可能不以与NH听者相同的方式检测非谐和性。

研究设计与样本

  • 受试者为12名听力正常(NH)听者和8名耳蜗听力损失30至50 dB(平均42 dB,0.25至3 kHz)的听者。
  • 采用自适应强迫选择程序测量同时呈现纯音的频率比变化检测阈值,标准频率比为谐和(2:1,即一个倍频程)或非谐和(0.8或1.2倍频程)。
  • 纯音在宽带噪声中以低感觉级(至多15 dB)呈现,以最小化耳蜗相互作用;主要实验条件下刺激的频率寄存器在每个试次内随机变化。

主要发现

  • 两组受试者在主要实验条件下,标准频率比为谐和时阈值均低于非谐和时。
  • 该谐和性敏感度效应对听力损失组部分成员较弱,但在频率辨别能力很差的受试者中仍可观察到。
  • NH组对负向偏离(压缩)的检测优于正向偏离(拉伸);听力损失组偏离方向对成绩无影响。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: A sum of simultaneous pure tones with harmonic relationships (i.e., simple frequency ratios) is normally heard as a single sound, with a single pitch, even when its components are fully resolved in the auditory periphery. This perceptual phenomenon called "harmonic fusion" is thought to play an important role in auditory scene analysis as listeners often have to segregate simultaneous harmonic sounds with different fundamental frequencies. The present study explored the consequences of mild or moderate cochlear hearing loss for the sensitivity to harmonicity and the detection of inharmonicity. DESIGN: The subjects were 12 normal-hearing (NH) listeners and 8 listeners with cochlear hearing loss amounting to 30 to 50 dB (mean: 42 dB) from 0.25 to 3 kHz. In each subject, thresholds for the detection of a change in the frequency ratio of simultaneous pure tones were measured with an adaptive forced-choice procedure. The standard frequency ratio was either harmonic (2:1, i.e., one octave) or inharmonic (0.8 or 1.2 octaves). The tones were presented at a low sensation level (at most 15 dB) within broadband noise, to minimize their cochlear interactions. In the main experimental conditions, the frequency register of the stimuli varied randomly within each trial, so that subjects were forced to process frequency ratios to achieve good performance; frequency discrimination was not sufficient. In other conditions, by contrast, frequency discrimination was sufficient to perform the task optimally. RESULTS: For both groups of subjects, thresholds in the main experimental conditions were lower (i.e., better) when the standard frequency ratio was harmonic than when it was inharmonic. This effect, revealing sensitivity to harmonicity, was weak for some members of the hearing-impaired group, but could be observed even in subjects showing a very poor frequency discrimination ability. The two groups, however, differed from each other with respect to the detection of inharmonicity: for the NH group, in agreement with previous results, negative deviations from one octave (i.e., compressions of this frequency ratio) were better detected than positive deviations (stretchings); for the hearing-impaired group, on the other hand, the sign of the deviations had no effect on performance. CONCLUSIONS: Sensitivity to harmonicity appears to be remarkably robust. However, it can be reduced in some listeners with mild or moderate cochlear damage. Moreover, as inharmonicity detection is asymmetric for NH listeners but apparently becomes symmetric in case of cochlear damage, it may be that listeners with cochlear damage do not detect inharmonicity in the same manner as NH listeners do. In some circumstances, inharmonicity can be detected on the basis of "beat" cues available in single frequency channels; however, the subjects tested here were unlikely to use cues of this type.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Bonnard D, Dauman R, Semal C, et al. The Effect of Cochlear Damage on the Sensitivity to Harmonicity. Ear Hear. 2017. PMID: 27992390

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。