移动听力计在安静与噪声环境中评估听力损失的准确性
前瞻性临床研究纳入33名成人,在安静与50 dB背景噪声隔声室内用消费级与专业级两款平板听力应用测听,并与常规听力图比较。消费级与专业级应用在安静环境中分别有91.1%和95.8%的阈值在常规听力图10 dB以内;筛查中度以上听力损失时,消费级应用敏感度87.5%、特异度95.9%,专业级应用分别为100%和95.9%。结论认为移动听力计可正确估计纯音阈值并筛查中度听力损失,降噪策略为临床外听力评估提供便携有效方案。
要点
- 安静隔声室内消费级与专业级应用分别有91.1%和95.8%的阈值在常规听力图10 dB以内。
- 噪声隔声室内经降噪后消费级与专业级应用分别有86.5%和91.3%的阈值在常规听力图10 dB以内。
- 筛查纯音平均>40 dB HL的中度以上听力损失,消费级应用敏感度87.5%、特异度95.9%,专业级应用分别为100%和95.9%。
核心结论
- 移动听力计可正确估计纯音阈值并筛查中度听力损失。
- 移动听力计中的降噪策略为临床环境外的听力评估提供便携有效方案。
研究设计与样本
- 前瞻性临床研究,纳入33名伴或不伴听力损失的成人,平均年龄49.7岁,女性占42.4%。
- 在三级医院比较常规听力图与平板设备上两款听力应用(消费级与专业级)测得的纯音平均及单频率气导阈值。
- 移动听力计在安静隔声室与50 dB背景噪声隔声室中分别采用主动与被动降噪策略进行测试。
主要发现
- 安静隔声室内,消费级应用91.1%(95%CI 89.1%-93.2%)与专业级应用95.8%(95%CI 93.5%-97.1%)的阈值在常规听力图对应阈值10 dB以内。
- 噪声隔声室内经降噪后,消费级应用86.5%(95%CI 82.6%-88.5%)与专业级应用91.3%(95%CI 88.5%-92.8%)的阈值在常规听力图对应阈值10 dB以内。
- 筛查纯音平均>40 dB HL的中度以上听力损失时,消费级应用敏感度87.5%、特异度95.9%,专业级应用敏感度100%、特异度95.9%。
- 总体上患者更偏好移动听力计而非常规听力图。
临床怎么用
- 原文结论认为移动听力计可正确估计纯音阈值并筛查中度听力损失。
- 原文结论认为移动听力计中的降噪策略为临床环境外的听力评估提供便携有效方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objectives (1) To compare the accuracy of 2 previously validated mobile-based hearing tests in determining pure tone thresholds and screening for hearing loss. (2) To determine the accuracy of mobile audiometry in noisy environments through noise reduction strategies. Study Design Prospective clinical study. Setting Tertiary hospital. Subjects and Methods Thirty-three adults with or without hearing loss were tested (mean age, 49.7 years; women, 42.4%). Air conduction thresholds measured as pure tone average and at individual frequencies were assessed by conventional audiogram and by 2 audiometric applications (consumer and professional) on a tablet device. Mobile audiometry was performed in a quiet sound booth and in a noisy sound booth (50 dB of background noise) through active and passive noise reduction strategies. Results On average, 91.1% (95% confidence interval [95% CI], 89.1%-93.2%) and 95.8% (95% CI, 93.5%-97.1%) of the threshold values obtained in a quiet sound booth with the consumer and professional applications, respectively, were within 10 dB of the corresponding audiogram thresholds, as compared with 86.5% (95% CI, 82.6%-88.5%) and 91.3% (95% CI, 88.5%-92.8%) in a noisy sound booth through noise cancellation. When screening for at least moderate hearing loss (pure tone average >40 dB HL), the consumer application showed a sensitivity and specificity of 87.5% and 95.9%, respectively, and the professional application, 100% and 95.9%. Overall, patients preferred mobile audiometry over conventional audiograms. Conclusion Mobile audiometry can correctly estimate pure tone thresholds and screen for moderate hearing loss. Noise reduction strategies in mobile audiometry provide a portable effective solution for hearing assessments outside clinical settings.
引用
- Saliba J, Al-Reefi M, Carriere JS, et al. Accuracy of Mobile-Based Audiometry in the Evaluation of Hearing Loss in Quiet and Noisy Environments. Otolaryngol Head Neck Surg. 2016. PMID: 28025906. doi:10.1177/0194599816683663
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。