基于视频评估睡眠呼吸障碍儿童扁桃体大小
这项前瞻性诊断准确性研究纳入169例拟行扁桃体切除术、腺样体切除术或腺扁桃体切除术的儿童,由家长使用手持远程医疗设备拍摄口咽视频,三名盲法儿科耳鼻咽喉科医生独立使用Brodsky量表评估扁桃体大小。结果显示评分者间一致性较强(Kendall's W=0.88),以面对面检查为参考标准,敏感度70%、特异度86%。
要点
- 家长拍摄口咽视频评估扁桃体大小与面对面检查相比敏感度70%、特异度86%。
- 三名评估者间一致性较强(Kendall's W=0.88),二分类后Fleiss κ=0.65。
- 12%的视频所有评估者均无法使用,32%至少一名评估者无法使用,低龄儿童更明显。
核心结论
- 家长拍摄的口咽视频可能为部分睡眠呼吸障碍儿童提供可行的远程扁桃体大小评估方法。
- 评分者间一致性较强且家长态度总体积极,支持进一步评估该方法。
- 在常规依赖视频评估进行手术决策前仍需额外验证。
研究设计与样本
- 前瞻性诊断准确性研究,在单一三级儿科转诊中心进行。
- 连续纳入169例计划行扁桃体切除术、腺样体切除术或腺扁桃体切除术的儿童。
- 家长使用手持远程医疗设备(TytoCare)拍摄口咽视频。
- 三名盲法儿科耳鼻咽喉科医生独立使用Brodsky量表评估扁桃体大小。
主要发现
- 169例儿童中位年龄4.4岁(IQR 3.3-7.6),53%行腺扁桃体切除术,46%仅行腺样体切除术。
- 扁桃体大小评分的评分者间一致性较强(Kendall's W=0.88,p<0.01)。
- 将评分二分为0-2级与3-4级时一致性仍显著(Fleiss κ=0.65,95% CI:0.58-0.73)。
- 以面对面检查为参考标准,敏感度70%、特异度86%、阳性预测值84%、阴性预测值73%。
关键数值与推荐
- 扁桃体大小采用Brodsky量表评估。
- 评分者间一致性:Kendall's W=0.88(p<0.01);二分类后Fleiss κ=0.65(95% CI:0.58-0.73)。
- 诊断性能:敏感度70%、特异度86%、阳性预测值84%、阴性预测值73%。
- 视频不可用率:12%被所有评估者判定不可用,32%至少被一名评估者判定不可用。
临床怎么用
- 在部分睡眠呼吸障碍儿童中,家长拍摄的口咽视频可作为远程扁桃体大小评估的可行方法。
- 视频评估结果需谨慎用于手术决策,常规依赖前仍需进一步验证。
- 低龄儿童视频不可用率较高,实际操作中需考虑此限制。
局限性
- 研究在单一三级儿科转诊中心进行,结果外推需谨慎。
- 12%的视频所有评估者均无法使用,32%至少一名评估者无法使用,低龄儿童中比例更高。
- 在常规依赖视频评估进行手术决策前仍需额外验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate whether parent-captured oropharyngeal videos obtained using a handheld telemedicine device can assess tonsil size in children with sleep-disordered breathing compared with in-person clinical examination. METHODS: We conducted a prospective diagnostic accuracy study at a single tertiary pediatric referral center. A consecutive sample of 169 children scheduled for tonsillectomy, adenoidectomy, or adenotonsillectomy was enrolled. Parents obtained oropharyngeal videos using a handheld telemedicine device (TytoCare). Three blinded pediatric otolaryngologists independently graded tonsil size using the Brodsky scale. Interrater agreement, diagnostic performance relative to in-person examination, and video usability were assessed. RESULTS: Among 169 children (median age 4.4 years, IQR 3.3-7.6), 53% underwent adenotonsillectomy and 46% adenoidectomy alone. Interrater agreement for tonsil size grading was strong (Kendall's W = 0.88, p < 0.01) and remained substantial when grades were dichotomized as 0-2 versus 3-4 (Fleiss κ = 0.65, 95% CI: 0.58-0.73). Using the in-person examination as the reference standard, sensitivity was 70%, specificity was 86%, positive predictive value was 84%, and negative predictive value was 73%. Twenty-one videos (12%) were unusable by all evaluators and 54 (32%) by at least one evaluator, with higher rates in younger children. CONCLUSION: Parent-captured oropharyngeal videos may provide a feasible method for remote tonsil size assessment in selected children with sleep-disordered breathing. Strong interrater agreement and generally favorable parental attitudes support further evaluation of this approach, while additional validation is needed before routine reliance on video-based assessment for surgical decision-making.
引用
- Livneh N, Wazana Y, Peled I, et al. Video-Based Assessment of Tonsil Size in Children With Sleep-Disordered Breathing. Laryngoscope. 2026. PMID: 42920092. doi:10.1002/lary.71014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。