视频可弯曲喉罩用于甲状腺手术中直视下喉返神经监测
这项前瞻性单臂研究纳入104例甲状腺手术患者,评估视频可弯曲喉罩(VFLMA)同期通气与直视喉返神经(RLN)监测的可行性。94.2%患者实现有效通气并完成RLN监测,6例需改气管插管;137条监测神经中7条(5.1%)出现信号丢失并与术后暂时性声带麻痹相关。研究为探索性可行性研究,结论需对照研究验证。
要点
- VFLMA可同时通气与直视RLN监测,104例中98例(94.2%)成功。
- 6例(5.8%)改气管插管,仅2例(1.9%)发生于术中。
- 137条神经中7条(5.1%)信号丢失,与暂时性声带麻痹相关。
核心结论
- VFLMA在甲状腺手术中实现直视RLN监测并保持可接受的通气成功率。
- 初步发现为假设生成性,需对照研究验证。
- 在合适患者选择下,VFLMA可能为RLN监测提供替代方法。
研究设计与样本
- 前瞻性单臂可行性研究,连续纳入104例甲状腺手术患者。
- VFLMA在诱导后提供实时声门视野。
- 主要结局为成功通气并完成RLN监测。
主要发现
- 104例中98例(94.2%)实现有效通气并RLN监测。
- 6例(5.8%)需改气管插管,其中仅2例(1.9%)发生于术中。
- 137条监测RLN中7条(5.1%)出现信号丢失,与术后暂时性声带麻痹相关。
- 观察到的敏感性、特异性及预测值为100%,因事件少95%CI较宽。
- ITT分析(n=104)中暂时性通气障碍发生率为气道压升高21.2%、反射性喉痉挛8.7%、暂时性漏气1.9%,均经简单处理缓解。
关键数值与推荐
- 有效通气并RLN监测成功定义为主要结局,104例中98例(94.2%)达到。
- RLN监测以刺激时声带运动为视觉判断标准。
- 信号丢失定义为监测RLN中7条(5.1%)出现。
临床怎么用
- 在合适患者选择下,可考虑VFLMA作为甲状腺手术RLN监测的替代通气方式。
- 术中需关注气道压升高、喉痉挛和漏气等通气障碍并及时处理。
- 信号丢失提示暂时性声带麻痹可能,需术后评估声带功能。
局限性
- 单臂探索性可行性研究,无对照组。
- RLN监测诊断性能因事件少而95%CI较宽。
- 结论为假设生成性,需比较研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the feasibility of a video flexible laryngeal mask airway (VFLMA) for simultaneous ventilation and direct visual RLN monitoring during thyroid surgery. METHODS: This prospective single-arm study enrolled 104 consecutive patients undergoing thyroid surgery, in whom the VFLMA provided real-time glottic views after induction. The primary outcome was successful ventilation with RLN monitoring. Secondary outcomes included diagnostic performance of visual RLN monitoring (vocal cord movement upon stimulation) and perioperative respiratory adverse events. RESULTS: Effective ventilation with RLN monitoring was achieved in 98 of 104 patients (94.2%). Six patients (5.8%) required conversion to endotracheal intubation with only 2 (1.9%) occurring during surgery. Among 137 monitored RLNs, loss of signal occurred in 7 (5.1%) and correlated with transient postoperative vocal fold palsy; observed sensitivity, specificity, and predictive values were 100% (95% CIs wide due to few events). Transient ventilatory disturbances occurred in 21.2% (elevated airway pressure), 8.7% (reflex laryngospasm), and 1.9% (transient air leakage) on ITT analysis (n = 104), all resolved with simple measures. Postoperative throat pain and odynophagia were mild and resolved within 1 week in most patients. CONCLUSIONS: In this exploratory feasibility study, the VFLMA enabled direct visual RLN monitoring during thyroid surgery with an acceptable ventilation success rate. These preliminary findings are hypothesis-generating and require validation in comparative studies. With appropriate patient selection, the VFLMA may offer an alternative approach for RLN monitoring. TRIAL REGISTRATION: The study was registered at www.chictr.org.cn (Identifier: ChiCTR2500105012).
引用
- Liu F, Huang J, Chen X, et al. Video Laryngeal Mask Airway for Visual Recurrent Laryngeal Nerve Monitoring in Thyroid Surgery. Laryngoscope. 2026. PMID: 42844016. doi:10.1002/lary.70973
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。