治疗性气道正压与药物诱导睡眠内镜下上气道塌陷性的关系
结果显示PhOP与中位CPAP及95%时间CPAP水平呈正相关,且PhOP分别低于两者1.5和3.3 cmH2O,提示治疗性CPAP水平可用于估算上气道塌陷性。
要点
- PhOP与mCPAP、t95CPAP呈正相关,可用于估算上气道塌陷性。
- PhOP分别比mCPAP和t95CPAP低1.5和3.3 cmH2O。
- mCPAP和t95CPAP每增加1单位,PhOP分别增加0.33和0.36 cmH2O。
核心结论
- mCPAP、t95CPAP与PhOP之间存在正相关,且PhOP低于治疗性CPAP水平。
- 这些发现可能使外科医生在无法进行DISE-PAP时,利用治疗性CPAP水平估算上气道塌陷性并决定手术干预。
主要发现
- 平均PhOP为7.1 ± 2.9 cmH2O,mCPAP为8.5 ± 2.4 cmH2O,t95CPAP为10.3 ± 2.5 cmH2O。
- PhOP与mCPAP呈正相关,PhOP比mCPAP低1.5 cmH2O,比t95CPAP低3.3 cmH2O。
- mCPAP和t95CPAP每增加1单位,PhOP分别增加0.33和0.36 cmH2O。
- BMI和AHI与mCPAP轻度相关;AHI每增加10点,mCPAP和PhOP分别增加0.4和0.3 cmH2O,但AHI与PhOP的关联未达统计学显著性。
临床怎么用
- 在DISE-PAP不可用时,外科医生可参考治疗性CPAP水平(mCPAP或t95CPAP)估算上气道塌陷性(PhOP),辅助制定手术干预决策。
局限性
- 证据等级为Level 4,为单中心回顾性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Drug-Induced Sleep Endoscopy with Positive Airway Pressure (DISE-PAP) provides quantitative evaluation of upper airway collapsibility, known as pharyngeal opening pressure (PhOP). Limited research exists on the relationship between PhOP and therapeutic continuous positive airway pressure (CPAP). This study investigated the relationship between therapeutic CPAP level and PhOP. STUDY DESIGN: Retrospective cohort study. SETTING: Single academic teaching hospital. METHODS: This study evaluated adults ≥18 years with obstructive sleep apnea (AHI ≥ 5) who underwent DISE-PAP from 2022 to 2024, had >2 h/d average PAP use, and well-controlled OSA on PAP. Primary outcome was the relationship between median CPAP level (mCPAP), CPAP level at 95% of time (t95CPAP), and PhOP. Secondary outcomes determined relationships between mCPAP, t95CPAP, and PhOP with AHI and BMI. RESULTS: Ninety-four patients were included (age 50.5 ± 15.1 years, BMI 29.9 ± 4.4 kg/m2, AHI 35.3 ± 23.3 events/h). Mean PhOP was 7.1 ± 2.9 cmH2O, mCPAP 8.5 ± 2.4 cmH2O, and t95CPAP 10.3 ± 2.5 cmH2O. Positive correlation existed between PhOP and mCPAP. PhOP was 1.5 and 3.3 cmH2O lower than mCPAP and t95CPAP, respectively. As mCPAP and t95CPAP increased by 1 unit, PhOP increased by 0.33 and 0.36 cmH2O. BMI and AHI were mildly correlated with mCPAP; for each 10-point increase in AHI, mCPAP and PhOP increased by 0.4 and 0.3 cmH2O, respectively. However, the association between AHI and PhOP did not reach statistical significance. CONCLUSION: Positive correlation exists between mCPAP, t95CPAP, and PhOP, with PhOP lower than therapeutic CPAP levels. These findings may allow surgeons to use therapeutic CPAP levels when DISE-PAP is unavailable to estimate upper airway collapsibility and determine surgical interventions. LEVEL OF EVIDENCE: Level 4.
引用
- Roque Buenrostro JA, Holland K, Chapman TA, et al. The Relationship of Therapeutic Positive Airway Pressure and Upper Airway Collapsibility During Drug-Induced Sleep Endoscopy. Otolaryngol Head Neck Surg. 2026. PMID: 42748373. doi:10.1002/ohn.70454
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。