文献速递耳科与耳神经

传统报告标准掩盖了鼓室成形术良好结果后的高频听力缺陷

Conventional Reporting Standards Conceal High-Frequency Hearing Deficits After Favorable Ossiculoplasty.
PubMed 文献 · Otolaryngol Head Neck Surg · 2026-08-04

这项多中心回顾性队列研究纳入499耳鼓室成形术病例,术后纯音平均气骨导差(PTA-ABG)≤15 dB,平均随访34.4个月。结果显示平均4 kHz ABG为18.2 dB,显著大于0.5-3 kHz,51.5%的耳4 kHz ABG≥20 dB,提示基于PTA的报告可能掩盖高频传导性听力损失。

要点

  • 即使PTA-ABG≤15 dB,4 kHz ABG仍可达18.2 dB,高频缺陷常见。
  • 51.5%的耳4 kHz ABG≥20 dB,26.7%≥25 dB,尽管符合成功标准。
  • 气导改善随频率升高而减小,4-8 kHz增益小于0.5-3 kHz。

核心结论

  • 基于PTA的报告标准可能显示鼓室成形术成功,但高频传导性缺陷仍持续存在。
  • 未来修改传导性听力损失报告标准时,应考虑纳入≥4 kHz的结果。

研究设计与样本

  • 回顾性队列研究,来自多中心三级护理鼓室成形术结果登记处。
  • 从1679例登记病例中纳入499耳,使用合成部分或全听骨链重建假体,术后0.5、1、2、3 kHz PTA-ABG≤15 dB,平均随访34.4±35.7个月。

主要发现

  • 术后平均PTA-ABG为9.6±3.7 dB。
  • 51.5%的耳4 kHz ABG≥20 dB,26.7%的耳4 kHz ABG≥25 dB。

临床怎么用

  • 临床评估鼓室成形术效果时,应关注高频听力结果,不能仅依赖PTA-ABG。
  • 对符合传统成功标准的患者,仍需评估4 kHz及以上的气骨导差。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate high-frequency hearing outcomes in ossiculoplasty cases having favorable pure-tone average outcomes within the reporting range set by current guidelines. STUDY DESIGN: Retrospective cohort study. SETTING: Multi-center tertiary care ossiculoplasty outcome registry. METHODS: From 1679 registry cases, 499 ears with synthetic partial or total ossicular replacement prostheses and postoperative pure-tone average air-bone gap (PTA-ABG) ≤ 15 dB at 0.5, 1, 2, and 3 kHz were included (mean follow-up, 34.4 ± 35.7 months). Outcomes included postoperative 4-kHz ABG and frequency-specific preoperative to postoperative changes in ABG and air-conduction (AC) thresholds. RESULTS: Mean postoperative PTA-ABG was 9.6 ± 3.7 dB. The mean 4-kHz ABG was larger (18.2 ± 10.9 dB) than ABGs at 0.5 to 3 kHz (P < .001). Despite meeting success criteria, 51.5% of ears had a 4-kHz ABG ≥ 20 dB and 26.7% had a 4-kHz ABG ≥ 25 dB. AC improvement decreased with increasing frequency; gains at 4 to 8 kHz were smaller than at 0.5 to 3 kHz (P < .001). CONCLUSION: Current PTA-based reporting can suggest ossiculoplasty has been successful while substantial high-frequency conductive deficits persist. Future modification of hearing outcome reporting standards for conductive hearing loss might benefit from consideration of ≥4-kHz outcomes.

来源:Otolaryngol Head Neck Surg,查看原文。版权归原作者所有。

引用

  1. Gluth MB, Judd RT. Conventional Reporting Standards Conceal High-Frequency Hearing Deficits After Favorable Ossiculoplasty. Otolaryngol Head Neck Surg. 2026. PMID: 42549507. doi:10.1002/ohn.70378

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。