内侧瓣与低温等离子辅助下鼻甲成形术治疗下鼻甲肥大的前瞻性随机对照试验
该前瞻性随机对照试验比较内侧瓣下鼻甲成形术(MFT)与低温等离子辅助下鼻甲成形术(CAT)治疗下鼻甲肥大所致持续性鼻塞的长期疗效。MFT组在12个月时症状缓解更优(NOSE:18.5 vs 34.5,P = .027;VAS:2.2 vs 4.0,P = .043),下鼻甲体积缩小更明显(P < .001)且术后结痂更少。结论认为两种术式均有效,但MFT长期结局更优、并发症更少。
要点
- MFT与CAT均可显著改善下鼻甲肥大患者的鼻塞症状。
- MFT在12个月时症状缓解及下鼻甲体积缩小均优于CAT。
- MFT术后结痂显著少于CAT,疼痛与恢复时间两组相当。
核心结论
- MFT与CAT均能有效改善下鼻甲肥大患者的鼻腔通气,但MFT长期结局更优且并发症更少。
研究设计与样本
- 前瞻性随机对照试验,纳入下鼻甲肥大且具备手术指征的患者,随机接受MFT或CAT。
- 结局评估者在不知晓手术方式的情况下进行评估。
主要发现
- 两组在基线及术后1、3、6、12个月的所有时间点症状均显著改善(P < .0001)。
- 早期 outcomes 两组相似,但MFT组在12个月时症状缓解显著更优(NOSE:18.5 vs 34.5,P = .027;VAS:2.2 vs 4.0,P = .043)。
- MFT组下鼻甲体积缩小更明显(P < .001),且术后结痂显著少于CAT组。
- 两组疼痛评分与恢复时间相当。
临床怎么用
- 对于药物治疗失败的下鼻甲肥大患者,MFT和CAT均为有效术式。
- 在合适选择的患者中,MFT可提供更优的长期症状缓解并减少术后结痂。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Inferior turbinate (IT) hypertrophy is a common cause of nasal obstruction. Surgical intervention may be required when medical treatment fails. This study compares the long-term efficacy of medial-flap turbinoplasty (MFT) and coblation-assisted turbinoplasty (CAT) in patients with persistent nasal obstruction. STUDY DESIGN: A prospective, randomized controlled trial. SETTING: Otolaryngology department-hospital and ambulatory clinics. METHODS: Patients with IT hypertrophy who were surgical candidates were assigned to undergo either MFT or CAT. Symptom severity was assessed using the NOSE scale and VAS for nasal obstruction at baseline and at 1, 3, 6, and 12 months postoperatively. Secondary outcomes included endoscopic assessment of turbinate size, postoperative complications, and pain. Outcome examiners were blinded to the surgical technique. RESULTS: Forty-four patients completed the study (MFT: 21; CAT: 23). Both groups showed significant symptom improvement at all time points (P < .0001). While early outcomes were similar, the MFT group demonstrated significantly greater long-term symptom relief at 12 months (NOSE: 18.5 vs 34.5, P = .027; VAS: 2.2 vs 4.0, P = .043). MFT also showed greater turbinate size reduction (P < .001) and was associated with significantly less postoperative crusting. Pain scores and recovery times were comparable between groups. CONCLUSION: Both MFT and CAT are effective in improving nasal breathing in patients with IT hypertrophy. However, MFT demonstrated superior long-term outcomes and fewer complications, supporting this technique in appropriately selected patients.
引用
- Daoud A, Geva S, Dror A, et al. Medial Flap Versus Coblation-Assisted Turbinoplasty For Turbinates Hypertrophy: A Prospective Randomized Controlled Trial. Otolaryngol Head Neck Surg. 2026. PMID: 42398225. doi:10.1002/ohn.70335