软手术技术下人工耳蜗植入的听力保留率
本研究分析成人人工耳蜗植入患者10年间听力保留率的变化,并探讨性别、年龄、围手术期类固醇剂量和电极类型与听力保留的关系。单因素分析显示较高剂量围手术期类固醇与听力保留改善显著相关(36.4% vs. 15%),手术年份较晚与听力保留率呈小幅但显著相关(r=0.22);多因素分析未发现任何因素显著相关。低频听力保留的单因素分析同样显示高剂量类固醇和时间显著(33% vs. 14.8%)。
要点
- 较高剂量围手术期类固醇与听力保留改善显著相关(36.4% vs. 15%)。
- 手术年份较晚与听力保留率呈小幅但显著相关(r=0.22)。
- 多因素分析未发现任何因素与听力保留显著相关。
核心结论
- 使用软手术技术时,听力保留率随时间呈小幅但显著的改善。
- 较高剂量围手术期类固醇与听力保留显著相关。
研究设计与样本
- 回顾性分析成人人工耳蜗植入患者10年间的听力保留率。
主要发现
- 单因素分析中,较高剂量围手术期类固醇组听力保留率为36.4%,较低剂量组为15%,差异有统计学意义。
- 手术年份较晚与听力保留率改善呈小幅但显著相关(r=0.22)。
- 多因素分析未发现性别、年龄、电极类型、类固醇剂量或手术年份与听力保留显著相关。
- 低频听力保留的单因素分析中,较高剂量类固醇组为33%,较低剂量组为14.8%,差异有统计学意义。
- 基于手术年份与类固醇剂量相关性的模型显示,二者与听力保留显著相关(r=0.21)。
临床怎么用
- 软手术技术下可考虑使用较高剂量围手术期类固醇以改善听力保留。
- 手术年份较晚可能与听力保留率改善相关,提示技术或经验积累的潜在影响。
局限性
- 多因素分析未发现显著相关因素,提示结果可能受混杂因素影响。
- 手术年份与类固醇剂量存在相关性,可能影响独立效应评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To determine if hearing preservation rates after cochlear implantation varied over time with soft surgery techniques. METHODS: The hearing preservation rate over time in adult cochlear implant patients over 10 years was analyzed. The association between hearing preservation rate and sex, age, perioperative steroid dose, and type of electrode was analyzed. Low frequency hearing preservation was analyzed separately. RESULTS: There was no statistical difference with sex, age, or type of electrode. There was a statistically significant improvement in hearing preservation with a higher dose of perioperative steroid on univariate analysis (36.4% vs. 15%). There was a small but significant correlation (r = 0.22) between improved rate and later year of implantation. However, no statistically significant correlation was identified for any factor on multivariate analysis. Date of surgery and steroid dose were correlated and, when the correlation was modeled, there was still no correlation with hearing preservation. For low frequency hearing preservation, a higher dose of perioperative steroids and time were also found to be significant on univariate analysis (33% vs. 14.8%). Multivariate analysis did not show significance for any factor, but the date of surgery and steroid dose were noted to be correlated. Model based on the correlation showed that date of surgery and steroid dose were significantly correlated with hearing preservation (r = 0.21). CONCLUSIONS: There was a small but significant correlation between the hearing preservation rate over time with the use of soft surgery techniques including a significant difference with the use of a higher steroid dose.
引用
- Huang TC, Lunos S. Hearing Preservation Rates After Cochlear Implantation Using Soft Surgery Techniques. Laryngoscope. 2026. PMID: 42273910. doi:10.1002/lary.70664
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。