儿童人工耳蜗植入者电极触点位于功能性听力区的分析
回顾性分析69耳保留低频听力的儿童人工耳蜗植入者,90%至少有一个电极触点位于功能性声听力区。对29例电声刺激使用者,触点接近度与激活后3、6、12个月安静环境下CNC词识别无显著关联。
要点
- 90%保留听力的儿童CI耳至少一个电极触点位于功能性听力区。
- EAS使用者中触点接近度与安静下词识别无显著关联。
- 需进一步研究儿童EAS使用者噪声下言语识别及个体化电极选择。
核心结论
- 多数保留听力的儿童CI植入者至少有一个电极触点位于功能性声听力区。
- EAS使用者中触点接近度与安静下词识别无显著关联,但亚组样本量有限。
研究设计与样本
- 三级转诊中心回顾性综述,纳入69耳保留低频听力(250 Hz无助听听阈≤80 dB HL)的直电极阵列儿童CI植入者。
- 术中使用X线确定每个电极的角度插入深度(AID),结合术后无助听听阈计算触点与功能性声听力区的接近度。
- 对EAS使用者(n=29)回顾激活后3、6、12个月安静环境下CNC词识别的关联。
主要发现
- 69耳中90%至少有一个电极触点位于功能性声听力区。
- 接近度值为-131°至450°(均值100°,SD 120°)。
- 29例有言语识别数据的EAS使用者中,接近度与激活后CNC评分无显著关联(p ≥ 0.212)。
关键数值与推荐
- 保留低频听力定义为250 Hz无助听听阈≤80 dB HL。
- EAS使用者接近度与CNC词识别关联无统计学显著性(p ≥ 0.212)。
临床怎么用
- 儿童CI植入保留听力时,多数耳至少一个电极触点位于功能性声听力区,需关注电极位置。
- 现有数据不支持仅凭触点接近度预测EAS使用者安静下词识别表现。
局限性
- EAS使用者亚组样本量有限。
- 未评估噪声下言语识别及个体化阵列选择或EAS调图的获益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Examine the incidence of one or more electrode contacts placed within the region of functional acoustic hearing and the potential influence of electrode positioning on speech recognition for pediatric cochlear implant (CI) recipients. METHODS: A retrospective review for pediatric CI recipients of straight electrode arrays with preserved low-frequency hearing (an unaided threshold of ≤ 80 dB HL at 250 Hz) was conducted at a tertiary referral center. Intraoperative X-rays were used to determine the angular insertion depth (AID) of each electrode. Proximity of contacts to the functional acoustic hearing region was calculated using AID and postoperative unaided thresholds. For electric-acoustic stimulation (EAS) users, the association between proximity values and CNC word recognition in quiet was reviewed at 3-, 6-, and 12-months post-activation. RESULTS: Among 69 ears, 90% had at least one electrode contact within the functional acoustic hearing region. Proximity values ranged from -131° to 450° (mean: 100°, SD: 120°). For EAS users with speech recognition data (n = 29), proximity values were not significantly associated with post-activation CNC scores (p ≥ 0.212). CONCLUSIONS: Most pediatric CI recipients with hearing preservation had at least one electrode contact in the region of functional acoustic hearing. Proximity was not significantly associated with word recognition in quiet for EAS users, though this subgroup was limited in sample size. Further studies in pediatric EAS users are needed to understand the potential relationship with speech recognition in noise and to determine the benefits of individualizing array selection and/or EAS mapping.