耳蜗电图SP/AP比值与单侧梅尼埃病内淋巴积水相关性
该回顾性研究纳入162例单侧梅尼埃病患者,采用钆增强MRI评估内淋巴积水(EH),并行耳蜗电图(ECochG)测量SP/AP比值。患耳SP/AP比值与耳蜗及前庭EH严重程度显著相关(r=0.483与r=0.476,均P<.001),ROC曲线下面积0.79,最佳截断值0.305(敏感度83.33%,特异度72.22%)。结论认为SP/AP比值对MD诊断及EH评估有较好价值。
要点
- 患耳SP/AP比值显著高于健耳(0.41±0.17 vs 0.24±0.12,P<.001)。
- SP/AP与耳蜗及前庭EH严重程度均显著相关(r=0.483与r=0.476)。
- 鉴别患耳的最佳SP/AP截断值为0.305,AUC为0.79。
核心结论
- ECochG SP/AP比值对梅尼埃病具有较强诊断效用,且与内淋巴积水严重程度显著相关。
- SP/AP截断值0.305可作为早期MD诊断和EH评估的可靠客观指标,尤其适用于无法进行MRI的机构。
研究设计与样本
- 回顾性研究,纳入162例单侧梅尼埃病患者。
- 研究地点为中山大学孙逸仙纪念医院。
- 采用钆增强MRI评估内淋巴积水,并行耳蜗电图测量SP/AP比值。
主要发现
- 患耳平均纯音听阈(PTA)显著高于健耳(51.0±17.9 dB vs 21.4±10.6 dB,P<.001)。
- 患耳ECochG SP/AP比值显著高于健耳(0.41±0.17 vs 0.24±0.12,P<.001)。
- SP/AP比值与耳蜗EH(r=0.483,P<.001)及前庭EH(r=0.476,P<.001)均显著相关。
- ROC分析显示鉴别患耳的AUC为0.79,最佳SP/AP截断值0.305(敏感度83.33%,特异度72.22%)。
关键数值与推荐
- 最佳SP/AP截断值为0.305,敏感度83.33%,特异度72.22%。
- SP/AP与耳蜗EH相关系数r=0.483(P<.001),与前庭EH相关系数r=0.476(P<.001)。
临床怎么用
- ECochG SP/AP比值可作为梅尼埃病临床决策的辅助工具。
- 在MRI不可用时,SP/AP截断值0.305有助于早期MD诊断和EH评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the optimal cut-off value of the electrocochleography (ECochG) SP/AP ratio and evaluate its correlation with endolymphatic hydrops (EH) in patients with unilateral Ménière's disease (MD). STUDY DESIGN: Retrospective study. SETTING: Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University. METHODS: This retrospective study enrolled 162 patients with unilateral MD. EH was assessed using gadolinium-enhanced MRI, and ECochG was performed to measure the SP/AP ratio. The correlation between SP/AP and EH severity was analyzed. RESULTS: The mean pure-tone average (PTA) threshold was significantly higher in affected ears than in unaffected ears (51.0 ± 17.9 dB vs 21.4 ± 10.6 dB, P < .001). The ECochG SP/AP ratio was also elevated in affected ears (0.41 ± 0.17 vs 0.24 ± 0.12, P < .001) and showed significant correlations with cochlear (r = 0.483, P < .001) and vestibular EH (r = 0.476, P < .001). Receiver operating characteristic (ROC) analysis revealed an area under the curve (AUC) of 0.79 for distinguishing affected ears, with an optimal SP/AP cut-off value of 0.305 (sensitivity = 83.33%, specificity = 72.22%). CONCLUSION: The ECochG SP/AP ratio demonstrates strong diagnostic utility for MD and correlates significantly with EH severity. A cut-off value of 0.305 provides a reliable objective marker for early MD diagnosis and EH assessment, particularly in settings where MRI is unavailable. ECochG serves as a valuable adjunctive tool for clinical decision-making in MD management.
引用
- Deng W, Li Z, Tang X, et al. Correlation of Electrocochleography SP/AP With Endolymphatic Hydrops in Unilateral Ménières Disease. Otolaryngol Head Neck Surg. 2026. PMID: 42037364. doi:10.1002/ohn.70252
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。