文献速递咽喉与嗓音

光学相干断层扫描量化猪声带脱水衰减效应

Quantifying Dehydration Effects of Porcine Vocal Fold Attenuation With Optical Coherence Tomography.
PubMed 文献 · Laryngoscope · 2026-03-26

本研究用光学相干断层扫描(OCT)表征猪声带组织脱水对光学衰减系数的影响。6个猪喉分为12个声带,经真空烘箱系列脱水至约5%、10%、15%质量损失,各阶段OCT扫描并提取衰减系数。结果显示组织质量每损失1%,衰减约下降0.08 mm-1,真声带衰减比假声带平均高1.47 mm-1,提示OCT可作为声带水合的非侵入性光学生物标志物。

要点

  • 组织质量每损失1%,OCT衰减系数约下降0.08 mm-1。
  • 真声带衰减值平均比假声带高1.47 mm-1。
  • OCT衰减可定量、可重复地反映声带脱水程度。

核心结论

  • OCT衍生的衰减系数是声带脱水的定量、可重复指标。
  • 衰减与组织质量损失呈线性关系,支持OCT作为声带水合的非侵入性光学生物标志物。

研究设计与样本

  • 研究使用6个猪喉,二分得到12个声带。
  • 每个标本经真空烘箱系列脱水至约5%、10%、15%质量损失,各阶段用1300 nm波长OCT系统扫描。
  • 通过自定义MATLAB处理从OCT B扫描提取衰减系数,并用线性混合效应模型分析脱水与衰减的关系。

主要发现

  • 组织质量每增加1%损失,衰减系数约下降0.08 mm-1(b = -0.079,95% CI [-0.105, -0.054])。
  • 衰减随组织脱水增加呈线性下降。
  • 真声带衰减值始终高于假声带,平均高1.47 mm-1(p < 0.001)。
  • 声带间变异性低(ICC = 0.041),表明跨标本重现性强。

临床怎么用

  • OCT衰减系数有望用于临床无创监测声带水合状态。
  • 未来需多波长和体内研究将该方法转化为声带水合、水肿和病变形成的临床监测。

局限性

  • 研究为离体猪声带实验,尚未在体内验证。
  • 仅使用单一1300 nm波长系统,未来需多波长研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The purpose of this study is to use optical coherence tomography (OCT) to characterize the effect of dehydration on the optical attenuation coefficient of porcine vocal fold (VF) tissue. Assessing laryngeal hydration is clinically relevant for evaluating vocal function; however, no reliable noninvasive methods currently exist to quantify it. METHODS: Six porcine larynges were bisected into 12 halves, yielding 12 VFs. Each specimen underwent serial dehydration using a vacuum oven to approximately 5%, 10%, and 15% mass loss, with OCT scans obtained at each interval using a 1300 nm wavelength system. Attenuation coefficients were extracted from OCT B-scans through custom MATLAB processing, and the relationship between tissue dehydration and attenuation was modeled using a linear mixed-effects model. RESULTS: Across VFs, attenuation decreased by approximately 0.08 mm-1 for each 1% increase in tissue mass loss (b = -0.079, 95% CI [-0.105, -0.054]). Attenuation decreased linearly with increasing tissue dehydration. The true VF exhibited consistently higher attenuation values than the false folds by an average of 1.47 mm-1 (p < 0.001). Interfold variability was low (ICC = 0.041), indicating strong reproducibility across specimens. CONCLUSIONS: OCT-derived attenuation provides a quantitative, reproducible indicator of VF dehydration. The linear relationship between attenuation and tissue mass loss supports the feasibility of OCT as a noninvasive optical biomarker of VF hydration. Future multi-wavelength and in vivo studies will be critical to translate this approach into clinical monitoring of VF hydration, edema, and lesion formation. LEVEL OF EVIDENCE: NA.

来源:Laryngoscope,查看原文。版权归原作者所有。