文献速递耳科与耳神经小儿耳鼻咽喉

非隔音室平板听力计在儿科中的验证:与传统听力计比较

Validation of Non-Soundproof Tablet Audiometry in Pediatrics: Comparison With Traditional Audiometry.
PubMed 文献 · Laryngoscope · 2026-03-19

本研究在儿科听力门诊招募4至17.9岁儿童,比较非隔音室平板听力计SHOEBOX与传统隔音室纯音测听的阈值,发现平板听力计诊断听力损失的敏感度为92%、特异度为85%,重测信度高,适用于能完成测试的5至17岁儿童。

要点

  • 平板听力计与传统纯音测听阈值平均差异-0.95 dB(95%CI -1.5至-0.42 dB)。
  • 诊断听力损失的敏感度92%(95%CI 84%-97%),特异度85%(95%CI 77%-92%)。
  • 重测信度高,93%(55/59)的阈值差异在±5 dB内。

核心结论

  • 非隔音室平板听力计对能完成测试的5至17岁儿童是有效且可靠的。

研究设计与样本

  • 在儿科听力门诊招募4至17.9岁儿童,以隔音室传统纯音测听为金标准进行比较。

主要发现

  • 120名儿童接受平板听力计测试,但并非全部能完成。
  • 948个测试频率中,平板与传统听力计平均阈值差异为-0.95 dB(95%CI -1.5至-0.42 dB)。
  • 92%(873个)的平板听力阈值在传统听力阈值10 dB以内。
  • 平板听力计诊断听力损失的敏感度为92%(95%CI 84%-97%),特异度为85%(95%CI 77%-92%)。
  • 重测信度高,93%(55/59)的阈值差异在±5 dB内。

关键数值与推荐

  • 听力损失定义为至少一个频率的听阈>20 dB。
  • 平板听力计测试6个频率(250-8000 Hz)。

临床怎么用

  • 平板听力计可作为远程听力测试工具,适用于学校、诊所和研究场景。

局限性

  • 并非所有儿童都能完成平板听力计测试。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Portable, tablet-based audiometry has been proposed as a diagnostic tool for patients unable to access traditional sound booth audiometry. However, the validity of tablet-based audiometry for diagnostic use in pediatric patients has not been established. The objective of this study is to validate self-administered tablet-based diagnostic audiometry in a pediatric clinic setting. METHODS: Children 4 to 17.9 years-old were recruited from a pediatric audiology clinic. Tablet audiometry was performed with tablet-based software, SHOEBOX Audiometry (Ottawa, ON) at six frequencies (250-8000 Hz). Hearing thresholds from traditional pure tone audiometry in a sound booth were used as a gold-standard comparison. Hearing loss was defined as ≥ 1 hearing threshold of > 20 dB. RESULTS: 120 children underwent tablet-audiometry, though not all were able to complete the test. In 948 individual frequencies tested, the mean threshold difference was -0.95 dB (95% CI -1.5 to -0.42 dB) between traditional and tablet audiogram. Most tablet-assessed thresholds (92%, n = 873) were within 10 dB of corresponding traditional audiometry thresholds. Tablet audiometry demonstrated 92% sensitivity (95% CI 84%-97%) and 85% specificity (95% CI 77%-92%) for diagnosis of hearing loss. Test-retest reliability of tablet audiometry was high, with 93% (55/59) of test-retest hearing threshold differences falling within ±5 dB. CONCLUSION: Tablet audiometry is valid and reliable for children aged 5-17 years who can successfully complete testing in a non-soundproof clinic setting. It may serve as a tool for remote hearing testing, with potential applications in schools, clinics, and research.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Ensing AE, Mueller L, Lee DS, et al. Validation of Non-Soundproof Tablet Audiometry in Pediatrics: Comparison With Traditional Audiometry. Laryngoscope. 2026. PMID: 41856760. doi:10.1002/lary.70514

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。