文献速递耳科与耳神经

耳蜗植入电极位于声学区域:长期听力保留情况

Cochlear Implant Recipients With Electrodes in the Acoustic Region: Long-Term Hearing Preservation.
PubMed 文献 · Laryngoscope · 2026-03-08

结果显示电极邻近度、角插入深度等变量均不能显著预测1年或≥3年无助听阈值变化(p≥0.128),更深插入或电极位于功能声学区域不导致延迟性残余听力损失。

要点

  • 电极邻近度与角插入深度均未显著预测1年及≥3年无助听听力阈值变化。
  • 更深插入或电极位于功能声学区域不增加延迟性残余听力损失风险。
  • 开机时保留低频听力的成人直电极植入者可长期维持残余听力。

核心结论

  • 更深插入深度及电极阵列位于功能声学听力区域不会使耳蜗植入者易发生延迟性残余听力损失。

主要发现

  • 角插入深度范围为330°至717°(均值513°,标准差79°)。
  • 电极邻近度范围为-183°至442°(均值35°,标准差110°)。
  • 电极邻近度、角插入深度、年龄、生理性别及术前低频纯音平均均未显著预测1年或≥3年随访时无助听听力阈值变化(p≥0.128)。

临床怎么用

  • 对于开机时保留低频听力的成人直电极植入者,可预期电极位于功能声学区域或更深插入不会导致延迟性残余听力损失。

局限性

  • 本研究为回顾性设计,仅纳入使用直电极阵列的成人患者,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: It is unknown how electrode array position in the cochlea influences long-term hearing preservation for cochlear implant (CI) recipients with preserved low-frequency hearing after surgery. The aim of this study was to evaluate the influence of electrode insertion depth relative to regions of post-operative acoustic hearing and hearing preservation ≥ 1 year after CI activation. METHODS: A retrospective review of adult CI recipients of a straight electrode array from 2017 to 2022 with functional acoustic hearing preservation (≤ 80 dB HL at 250 Hz) at device activation was performed. Proximity was quantified as the angular insertion depth (AID) of the most apical contact relative to the region of preserved functional acoustic hearing. Positive values indicate placement within the functional acoustic region; negative values indicate placement basal to the functional acoustic region. Low-frequency pure tone average (LFPTA) was queried from the preoperative, device activation, and annual post-activation visits. Stepwise regression analyzed whether proximity, AID, age, biological sex, and pre-operative LFPTA were significant predictors for change in unaided hearing thresholds. RESULTS: One hundred and six CI recipients met inclusion criteria. AID ranged from 330° to 717° (mean 513°, SD 79°). Proximity values ranged from -183° to 442° (mean 35°, SD 110°). None of the reviewed independent variables, including proximity, significantly predicted unaided hearing threshold shifts at the 1-year or the ≥ 3-year visits (p ≥ 0.128). CONCLUSION: Deeper insertion depths and electrode array placement within the functional acoustic hearing region did not predispose CI recipients to delayed loss of residual hearing.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Thompson NJ, Brown KD, Buss E, et al. Cochlear Implant Recipients With Electrodes in the Acoustic Region: Long-Term Hearing Preservation. Laryngoscope. 2026. PMID: 41796981. doi:10.1002/lary.70472

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。