噪声暴露后暂时性听力症状者的噪声中纯音检测受损
本研究在军人中开展两项实验,测量500 Hz噪声中纯音检测阈值,并收集听力问卷。结果显示,报告噪声暴露后频繁听力症状者,其N0S0和N0Sπ检测阈值显著差于无症状者,且独立于纯音听阈;N0Sπ与听阈联合可多解释约50%的听力抱怨方差。
要点
- 报告噪声后频繁听力症状者噪声中纯音检测阈值更差,独立于纯音听阈。
- 噪声暴露史影响N0Sπ阈值,但效应小于暴露后症状。
- N0Sπ与听阈联合比单一因素多解释约50%听力抱怨方差。
核心结论
- 噪声暴露后暂时性阈值改变与听力损害相关,部分听者出现慢性损害并影响客观噪声中检测及主观听力困难。
研究设计与样本
- 实验1:4253名军人完成33试次掩蔽级差测试,测量500 Hz N0S0和N0Sπ检测阈值。
- 实验2:17658名军人完成18试次N0Sπ检测,用3206名完成两测试者数据转换为等效阈值。
- 收集纯音听阈、听力困难问卷、噪声暴露史及暴露后症状史,拟合线性模型。
主要发现
- 报告噪声后频繁听力症状者N0S0和N0Sπ阈值显著差于无症状者,控制纯音听阈后仍存在。
- 组间差异在听力阈值较好者最小,随听阈在正常范围内增加而系统增大。
- 噪声暴露史也影响N0Sπ阈值,但效应小于暴露后症状。
- N0Sπ与听阈联合解释听力抱怨评分方差比任一因素单独多约50%。
关键数值与推荐
- N0S0:500 Hz同相纯音在同相噪声中检测。
- N0Sπ:500 Hz反相纯音在同相噪声中检测。
- 实验1为33试次,实验2为18试次。
临床怎么用
- 建议在听力保护计划年度听力测试中增加暂时性阈值改变史和听力抱怨问题。
- 对纯音听阈正常但报告听力困难的噪声暴露患者,推荐增加双耳噪声中纯音检测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Current hearing conservation standards assume that changes in the pure-tone audiogram fully capture the effects of noise-induced hearing damage. However, recent data suggest that individuals who frequently experience acute hearing symptoms after noise exposure may suffer long-term increases in hearing difficulty, even when their pure-tone thresholds remain unchanged. It is unclear whether these increases in subjective hearing difficulties correspond to objective measures of hearing ability. This study explores (1) whether tone-in-noise detection is negatively impacted by a history of noise-induced temporary threshold shifts, (2) whether noise exposure history or the number of temporary threshold shifts after exposure is the better predictor of tone-in-noise detection, and (3) whether tone-in-noise detection provides insights into subjective hearing complaints independent of the audiogram. DESIGN: Two experiments were conducted to measure 500-Hz tone-in-noise detection thresholds among service members (SMs). Audiometric data were collected from SMs in addition to questionnaires about perceived hearing difficulties, noise exposure history, and history of hearing symptoms following noise exposure. In Experiment 1, 4253 SMs completed a 33-trial Masking Level Difference test that measured detection thresholds for a 500-Hz homophasic tone presented in homophasic noise (the N0S0 condition) and a 500 Hz antiphasic tone presented in homophasic noise (the N0Sπ condition). In Experiment 2, 17,658 SMs completed an 18-trial test measuring N0Sπ detection. Results from Experiment 2 were converted into N0Sπ detection thresholds equivalent to those in Experiment 1 using data from 3206 SMs who completed both tests. Linear models were then fit to the data to determine the effects of noise exposure history, symptoms experienced after exposure, and pure-tone audiometric thresholds on N0S0 and N0Sπ detection. Linear models were also used to determine the degree to which post-exposure symptoms, pure-tone audiometric thresholds, and N0Sπ detection could predict self-reported hearing complaints. RESULTS: Individuals who reported frequent hearing symptoms after noise exposure had substantially worse N0S0 and N0Sπ detection thresholds than those without these symptoms, even after controlling for pure-tone audiometric thresholds. Group differences were smallest for individuals who had good hearing thresholds and increased systematically as hearing thresholds increased within the normal range. Noise exposure history also influenced N0Sπ thresholds, but had a smaller effect than that of post-exposure symptoms. Finally, combining N0Sπ and hearing thresholds explained roughly 50% more of the variance in hearing complaint scores than either factor alone. CONCLUSIONS: These findings are consistent with results from animal models showing that temporary changes in hearing thresholds are associated with hearing damage. The results suggest that some listeners experience chronic hearing damage from the same noise exposures that have no effect on other listeners. Such auditory damage seems to impact subjective hearing difficulty, as reported previously, and objective tone-in-noise detection, as observed here. Evidence from this and other studies justifies the addition of questions regarding temporary threshold shift history and hearing complaints into all annual hearing tests conducted in hearing conservation programs. Adding a measure of binaural tone-in-noise detection to the clinical battery administered to noise-exposed patients who report hearing difficulties despite normal audiograms is also recommended.
引用
- Brungart DS, Ellis GM, Shub DE, et al. Impaired Tone-in-Noise Detection in Individuals Who Report Temporary Hearing Symptoms After Noise Exposure. Ear Hear. 2026. PMID: 41622525. doi:10.1097/AUD.0000000000001789
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。