文献速递耳科与耳神经

自动化前庭康复系统:机器视觉引导平台的常模数据

The Automated Vestibular Rehabilitation System: Normative Data From a Machine Vision-Guided Platform.
PubMed 文献 · Laryngoscope · 2026-02-06

本研究评估基于机器视觉的自动化前庭康复系统(AVRS)的可行性与性能。结果显示AVRS引导练习均能完成,VOR增益接近生理常模,但重测信度中等。

要点

  • AVRS在健康成人中可准确测量VOR增益,均值接近-1.0。
  • AVRS引导的前庭康复练习所有受试者均能成功完成。
  • 重测信度中等(ICC 0.59),支持其作为可扩展的VRT工具。

核心结论

  • AVRS在健康成人中显示出中等重测信度和准确的VOR增益测量,支持其作为可扩展、可及的前庭康复工具。

研究设计与样本

  • 重测信度在20名受试者子集中评估,使用组内相关系数(ICC)及95%置信区间。

主要发现

  • 所有参与者均成功完成AVRS引导的前庭练习。
  • 重测子集(n=20)在27±9天后返回,各次会话VOR增益均值接近生理常模(约-1.0),不受频率影响(会话1:-0.98±0.04;会话2:-0.99±0.03)。
  • 会话间总体重测信度中等(ICC(3,1):0.59 [95% CI:0.37-0.75],p < 0.001)。

关键数值与推荐

  • VOR增益通过中性头位附近眼动速度与头动速度比值的中位数和四分位距计算。

临床怎么用

  • AVRS可作为前庭康复治疗的可扩展、可及工具,其常模数据可指导临床人群的治疗进展。

局限性

  • 研究仅纳入健康成人,未涉及平衡障碍患者;重测信度仅为中等。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE(S): Vestibular rehabilitation therapy (VRT) is an efficient treatment for dizziness and vertigo, but its accessibility remains limited. This study evaluates the feasibility and performance of a machine vision-based automated alternative-the Automated Vestibular Rehabilitation System (AVRS)-as a more accessible approach to delivering VRT. METHODS: Forty age- and sex-matched adults without balance disorders or recent head injury completed one standard VRT exercise, X1, in seated and standing positions using the AVRS, which tracked real-time head and eye movements. Gain, the ratio of eye to head velocity near the neutral head position, was calculated using median values and interquartile ranges. Test-retest reliability (TRTR) was assessed in a subset of 20 participants using intraclass correlation coefficients (ICCs) with 95% confidence intervals. RESULTS: All participants successfully completed the AVRS-guided vestibular exercises. The n = 20 person test-retest reliability subset returned after 27 ± 9 days. Mean VOR gain approximated the expected physiologic norms (~-1.0) across sessions irrespective of frequency (Session 1: -0.98 ± 0.04; Session 2: -0.99 ± 0.03). Overall reliability between sessions was moderate (ICC (3, 1): 0.59 [95% CI: 0.37-0.75], p < 0.001). CONCLUSION: The AVRS demonstrated moderate reliability and accurate VOR gain measurement in healthy adults, supporting its potential as a scalable, accessible tool for VRT delivery, with normative data to guide therapeutic progression in clinical populations.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Williams E, Tribin FE, Diaz LR, et al. The Automated Vestibular Rehabilitation System: Normative Data From a Machine Vision-Guided Platform. Laryngoscope. 2026. PMID: 41649094. doi:10.1002/lary.70425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。