丙泊酚麻醉深度对药物诱导睡眠内镜下PAP滴定的影响
该前瞻性研究纳入17例OSA患者,在药物诱导睡眠内镜联合PAP滴定(DISE-PAP)中监测BIS,比较浅镇静(BIS≥55)与深镇静(BIS<55)下VOTE评分和咽部开放压(PhOP)的变化。结果显示PhOP与BIS读数显著相关(rho=-0.45,p=0.0328),而VOTE分类与BIS水平无显著相关(rho=0.18,p=0.189)。
要点
- DISE-PAP中BIS监测的麻醉深度与PhOP显著相关。
- VOTE分类与BIS水平无显著相关。
- 软腭和会厌的开放压与BIS水平相关。
核心结论
- BIS测量的麻醉深度与PhOP测量的气道阻力相关。
- PAP在DISE中可提供高度可滴定且即时的咽部塌陷性测量。
研究设计与样本
- 前瞻性研究,纳入17例OSA患者,在DISE-PAP中监测BIS。
- BIS≥55定义为浅镇静,BIS<55定义为深镇静。
主要发现
- 所有17例患者均患OSA,平均AHI为30.5,标准差17.8。
- PhOP与BIS读数显著相关(rho=-0.45,p=0.0328)。
- VOTE分类与BIS水平无显著相关(rho=0.18,p=0.189)。
- 软腭开放压与BIS水平相关(rho=-0.398;p=0.044)。
- 会厌开放压与BIS水平相关(rho=-0.426;p=0.038)。
关键数值与推荐
- PhOP定义为所有气道区域开放时的最小压力。
- VOTE评分由两名睡眠外科研究员之一或一名主治睡眠外科医生盲法评估视频。
临床怎么用
- DISE-PAP中可结合BIS监测麻醉深度以评估咽部塌陷性。
- PAP滴定可用于即时测量PhOP。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Airway collapsibility varies with the level of anesthetic depth during drug-induced sleep endoscopy (DISE). Bispectral index (BIS) monitoring uses EEG signals to quantify anesthetic depth. We conducted a prospective study to examine changes in VOTE scores and pharyngeal opening pressure (PhOP) during DISE with positive airway pressure (DISE-PAP), at light and deep sedation. METHODS: Anesthetic depth was monitored using BIS during DISE-PAP for 17 patients. We classified BIS ≥ 55 as light sedation and < 55 as deep sedation. The DISE exam was performed and subsequently PAP applied to assess PhOP at both light and deep sedation. We defined PhOP as the minimum pressure wherein all areas of the airway were opened. A blinded evaluation of the procedure video was performed by either one of two sleep surgery fellows or an attending sleep surgeon to create a VOTE score for the DISE exam and PhOP. RESULTS: All n = 17 patients enrolled had OSA with a mean AHI of 30.5 and standard deviation 17.8. PhOP significantly correlated with BIS readings (rho = -0.45, p = 0.0328) but VOTE classification did not significantly correlate with BIS level (rho = 0.18, p = 0.189). The velum and epiglottis had opening pressures that correlated to BIS level (rho = -0.398; p = 0.044) and (rho = -0.426; p = 0.038), respectively. CONCLUSIONS: Anesthetic depth measured by BIS correlates with airway resistance as measured by PhOP. PAP appears to be a useful tool during DISE as it gives a highly titratable and immediate measurement of pharyngeal collapsibility.
引用
- DeKloe J, Creighton E, Trivedi J, et al. Effects of Anesthetic Depth Using the Bispectral Index During Sleep Endoscopy With PAP Titration. Laryngoscope. 2026. PMID: 41562324. doi:10.1002/lary.70361