文献速递耳科与耳神经

人工耳蜗植入者纵向言语结局与心理物理学及功能脑成像识别的神经因素相关

Longitudinal Speech Outcomes in Cochlear Implant Recipients Are Associated With Neural Factors Identified Using Psychophysics and Functional Brain Imaging.
PubMed 文献 · Ear Hear · 2026-01-22

结果显示跨电极强度辨别能力较好和听觉皮层跨模态激活较小均与更好的言语理解显著相关,且两者联合可显著预测言语理解结局。

要点

  • 跨电极强度辨别能力与言语理解正相关(R²=0.138,p=0.047)。
  • 听觉皮层跨模态激活较小与更好言语理解相关(R²=0.216,p=0.01)。
  • 两项指标联合可显著预测言语理解结局(Adj R²=0.312,p=0.009)。

核心结论

  • 植入者特异的心理物理学与功能脑成像指标显著贡献言语理解结局的个体差异。

主要发现

  • 跨电极强度辨别能力较好与言语理解更好显著相关(R²=0.138,p=0.047)。
  • 听觉皮层跨模态激活较小与言语理解更好显著相关(R²=0.216,p=0.01)。
  • 两项指标联合显著预测言语理解结局(Adj R²=0.312,p=0.009)。

关键数值与推荐

  • 耳蜗内神经健康用聚焦心理物理学阈值估计。
  • 跨电极强度辨别能力用心理物理学「频谱倾斜」评估。
  • 听觉皮层跨模态激活用功能性近红外光谱评估。
  • 言语理解在开机1年时于竞争多说话者噪声中评估。

临床怎么用

  • 心理物理学与功能脑成像测试可识别不同植入者的特定限制,为个体化改善言语理解提供潜在方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: There remain large variations in cochlear implant auditory-speech perception ability, which are poorly explained by patient history factors. This study aims to better understand how combinations of speech processing limitations, identified using psychophysical and functional brain imaging measures, are associated with long-term speech understanding outcomes of new cochlear implant recipients. DESIGN: Forty-three cochlear implant recipients (44 ears) were recruited to participate in a longitudinal study to evaluate limitations at various locations along the auditory processing pathway. At the periphery, intra-cochlear neural health was estimated using focused psychophysical thresholds. Higher-order across-electrode intensity discrimination ability was assessed using psychophysical "spectral tilt." At the cortical level, cross-modal activation of the auditory cortex was assessed using functional near-infrared spectroscopy. Speech understanding outcomes were evaluated in competing multi-talker babble noise at 1-year post-device switch-on. RESULTS: We found that greater abilities to discriminate smaller across-electrode stimulation intensities ( R2 = 0.138, p = 0.047) and smaller cross-modal activations of the auditory cortex ( R2 = 0.216, p = 0.01) were significantly associated with better speech understanding outcomes in cochlear implant recipients. Furthermore, both measures contributed significantly to better predict speech understanding outcomes in a multiple regression model (Adj R2 = 0.312, p = 0.009). CONCLUSIONS: The results suggest that recipient-specific psychophysical and functional brain imaging metrics contribute significantly toward individual differences in speech understanding outcomes. Different recipients can be affected by different limitations, which can be identified using these tests, and therefore lead to potential patient-specific methods to improve their speech understanding.

来源:Ear Hear,查看原文。版权归原作者所有。

引用

  1. Peng T, Henshall KR, Esmaelpoor J, et al. Longitudinal Speech Outcomes in Cochlear Implant Recipients Are Associated With Neural Factors Identified Using Psychophysics and Functional Brain Imaging. Ear Hear. 2026. PMID: 41566523. doi:10.1097/AUD.0000000000001776

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。