文献速递耳科与耳神经

机器人辅助电极阵列植入可提高声学听力阈值的稳定性

Robotic-Assisted Electrode Array Insertion Improves Stability of Acoustic Hearing Thresholds.
PubMed 文献 · Laryngoscope · 2026-01-21

本研究比较了手动与机器人辅助电极阵列植入对人工耳蜗术后迟发性听力下降的影响。结果显示,机器人辅助组迟发性听力下降发生率显著低于手动组(7% vs 37%,p=0.002),12个月随访时机器人组无迟发性听力下降发生(0% vs 29%,p=0.011)。

要点

  • 机器人辅助电极植入可降低迟发性听力下降风险。
  • 12个月随访时机器人组迟发性听力下降发生率为0%。
  • 需治疗人数(NNT)为4。

核心结论

  • 机器人辅助电极阵列植入与迟发性听力下降发生率的临床有意义降低相关。
  • 保留残余声学听力是人工耳蜗手术的关键目标,机器人辅助植入有助于实现该目标。

研究设计与样本

  • 研究纳入60例手动电极植入的成年患者(AB 30例,MED-EL 30例)和29例机器人辅助植入的成年患者(AB 13例,MED-EL 16例),使用iotaSOFT系统。
  • 主要结局指标为低频纯音平均听阈(LFPTA)的纵向变化。
  • 迟发性听力下降定义为LFPTA较既往最佳术后LFPTA下降>10 dB。

主要发现

  • 在初始激活后12个月(±4周)有LFPTA数据的受试者中,手动组38例(AB 15例,MED-EL 23例)中11例(29%)出现迟发性听力下降,机器人辅助组18例(AB 8例,MED-EL 10例)中0例(0%)出现迟发性听力下降(p=0.011,Fisher精确检验,双尾)。
  • 需治疗人数(NNT)为4。

临床怎么用

  • 机器人辅助电极阵列植入可作为减少迟发性听力下降、保留残余听力的手术策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE(S): Robotic-assisted electrode array (EA) insertion is a promising technique that may enhance preservation of residual acoustic hearing after cochlear implant (CI) surgery. The purpose of this study is to evaluate the impact of robotic-assisted EA insertion on rates of delayed-onset hearing loss (DOHL). METHODS: Sixty (Advanced Bionics [AB]: 30, MED-EL: 30) adult patients underwent CI surgery with manual EA insertion and 29 (AB: 13, MED-EL: 16) with robotic-assisted insertion using the iotaSOFT system. The primary outcome variable was longitudinal change in low frequency pure-tone average (LFPTA). DOHL was defined as a decrease in LFPTA of > 10 dB compared to previous best postoperative LFPTA. RESULTS: Twenty-two (37%) out of the 60 subjects in the manual cohort and two (7%) out of the 29 subjects in the robotic-assisted cohort had DOHL over the entire length of available follow-up (p = 0.002, Fisher's exact test, two-tailed). When evaluating DOHL results for subjects who had LFPTA data at 12 months (±4 weeks) post initial activation, 11 (29%) out of the 38 (AB: 15, MED-EL: 23) subjects in the manual cohort and zero (0%) out of the 18 (AB: 8, MED-EL: 10) subjects in the robotic-assisted cohort had DOHL (p = 0.011, Fisher's exact test, two-tailed). The number needed to treat was 4. CONCLUSION: Robotic-assisted EA insertion is associated with a clinically meaningful reduction in rates of DOHL. Preservation of residual acoustic hearing is a critical goal in CI surgery, and robotic-assisted EA insertion contributes towards achieving this goal.

来源:Laryngoscope,查看原文。版权归原作者所有。

引用

  1. Khan UA, Scheperle RA, Podhajsky G, et al. Robotic-Assisted Electrode Array Insertion Improves Stability of Acoustic Hearing Thresholds. Laryngoscope. 2026. PMID: 41562332. doi:10.1002/lary.70380

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。