文献速递鼻科小儿耳鼻咽喉

Th2相关标志物对局部过敏性鼻炎的临床价值:诊断准确性meta分析与间接比较

Clinical utility of Th2-related markers for local allergic rhinitis: a meta-analysis and indirect comparison of diagnostic test accuracy.
PubMed 文献 · Rhinology · 2026-01-01

鼻特异性IgE特异度达100%但敏感度仅48.1%,鼻嗜酸性粒细胞敏感度最高(69.1%)但特异度最低(56.2%);间接比较显示BAT和nsIgE敏感度显著高于nEos。

要点

  • 鼻特异性IgE特异度100%但敏感度低(48.1%),阴性结果需鼻激发试验确认。
  • 鼻嗜酸性粒细胞敏感度最高(69.1%)但特异度最低(56.2%)。
  • BAT和nsIgE的敏感度在间接比较中显著高于nEos。

核心结论

  • 鼻特异性IgE和嗜碱性粒细胞活化试验可辅助诊断局部过敏性鼻炎,但敏感度较低。
  • 阴性结果应以鼻激发试验确认。
  • 所报告敏感度的异质性进一步凸显当前诊断方法的局限性。

研究设计与样本

  • 评估三种指标测试相比鼻激发试验对局部过敏性鼻炎的诊断准确性。
  • 采用间接比较计算指标测试间的相对诊断结果及95%置信区间。

主要发现

  • 三种生物标志物敏感度范围为48.1%至69.1%。
  • 鼻嗜酸性粒细胞敏感度最高但特异度最低(56.2%)。
  • 鼻特异性IgE特异度达100%、敏感度48.1%,诊断比值比最高(显著)、阳性似然比最高(不显著)。
  • 嗜碱性粒细胞活化试验的阴性似然比最低且具统计学显著性。
  • 间接比较显示BAT和nsIgE敏感度显著高于nEos。

关键数值与推荐

  • 鼻嗜酸性粒细胞:敏感度69.1%,特异度56.2%。
  • 鼻特异性IgE:敏感度48.1%,特异度100%,诊断比值比最高(显著),阳性似然比最高(不显著)。
  • 嗜碱性粒细胞活化试验:阴性似然比最低且具统计学显著性。
  • 间接比较:BAT和nsIgE敏感度显著高于nEos。

临床怎么用

  • 可将鼻特异性IgE和嗜碱性粒细胞活化试验作为局部过敏性鼻炎的辅助诊断工具。
  • 对上述标志物阴性但临床高度怀疑者,应行鼻激发试验确认。
  • 解读结果时需考虑各标志物敏感度与特异度的互补性。

局限性

  • 所报告敏感度存在异质性,提示当前诊断方法存在局限。
  • 鼻特异性IgE敏感度有限(48.1%)。
  • 嗜碱性粒细胞活化试验与鼻特异性IgE敏感度均较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The role of Th2-related biomarkers as a diagnostic tool for local allergic rhinitis (LAR) remains controversial. This study seeks to assess the clinical utility of these markers and rank their diagnostic accuracy for LAR. METHODS: Systematic searches were conducted across five electronic databases. Pooled outcomes, including sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR), were calculated. Relative diagnostic outcomes with a 95% confidence interval between index tests were computed using the indirect comparison of modalities. RESULTS: Twenty-one studies met the inclusion criteria, assessing the diagnostic accuracy of three index tests compared to nasal provocation test for LAR. Among the three biomarkers, sensitivities ranged from 48.1% to 69.1%, with nasal eosinophilia (nEos) showing the highest sensitivity but lowest specificity (56.2%). Nasal-specific IgE (nsIgE) demonstrated perfect specificity (100%) but limited sensitivity (48.1%), the highest DOR (significant), and the highest LR+ (not significant). Basophil activation test (BAT) had the lowest LR- with statistical significance. Indirect comparisons showed BAT and nsIgE had significantly higher sensitivities than nEos. CONCLUSIONS: Nasal-specific IgE and the basophil activation test can help diagnose local allergic rhinitis, but their sensitivities are low. Negative results should be confirmed with a nasal provocation test. Heterogeneity in reported sensitivities further underscores the limitations of current diagnostic methods.

来源:Rhinology,查看原文。版权归原作者所有。