人工耳蜗使用者外周神经可塑性的全生命周期研究
该多中心队列研究纳入7416例人工耳蜗使用者,开发并验证了自动分析电诱发复合动作电位的方法,发现植入年龄而非刺激时长是听神经反应性的主要决定因素,婴幼儿植入后5年内反应斜率持续增加,提示生命早期存在外周神经可塑性。
要点
- 植入年龄显著预测听神经反应斜率,婴幼儿期植入者斜率随使用时间持续增加。
- 阈值从耳蜗顶部至底部逐渐升高,反应斜率与平台相应下降,潜伏期稳定。
- 30岁后斜率与平台趋于稳定,提示早期植入对保留神经健康至关重要。
核心结论
- 植入年龄而非刺激时长是听神经反应性的主要决定因素。
- 生命早期存在外周神经可塑性,早期植入对保留神经健康和优化长期结局至关重要。
研究设计与样本
- 多中心队列研究,使用非线性曲线拟合模型分析临床编程和随访中获取的电诱发复合动作电位。
主要发现
- 两种模型成功拟合约80%的听神经生长函数。
- 阈值从耳蜗阵列顶部至底部逐渐升高,伴随反应斜率和平台下降,潜伏期在各电极位置保持稳定。
- 植入年龄显著预测神经反应斜率,年轻受者斜率更陡,随年龄增加而下降,尤其在青春期后。
- 婴幼儿植入后5年内斜率持续增加,提示生命早期外周神经可塑性;年长受者斜率随时间变化极小。
- 长期使用设备后阈值适度升高,但30岁后斜率和平台趋于稳定。
临床怎么用
- 可采用自动分析方法标准化评估人工耳蜗使用者的听神经功能。
- 应重视早期人工耳蜗植入以保留神经健康并优化长期结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
IMPORTANCE: Neural recordings from cochlear implant users provide a valuable, noninvasive measure of auditory nerve function. However, inconsistent methods for acquiring and analyzing these recordings limit their clinical application. OBJECTIVE: To develop and validate an automated method for standardizing the analysis of electrically evoked compound action potentials in cochlear implant users, and to characterize longitudinal changes in auditory nerve function across the largest cohort studied to date. DESIGN, SETTINGS, AND PARTICIPANTS: This multicenter cohort study used nonlinear curve-fitting models to analyze electrically evoked compound action potentials acquired during clinical programming and follow-up at multiple US centers from July 28, 2002, to August 13, 2017. Data were analyzed from October 8, 2024 to May 6, 2025. MAIN OUTCOMES AND MEASURES: Model fit success rates; variation in auditory nerve response parameters with age, sex, electrode location, and duration of implant use; and identification of age-related periods of peripheral neural plasticity. RESULTS: The analysis included 1 145 323 electrically evoked compound action potential recordings comprising 169 159 growth functions from 10 111 cochlear implants in 7416 patients (3560 [48%] female and 3856 [52%] male individuals). Both models successfully fit approximately 80% of auditory-nerve growth functions. Thresholds increased from apex to base along the cochlear array, paralleled by a decline in response slope and plateau. Latencies remained stable across electrode locations. Age at implantation significantly predicted nerve response slope, with younger recipients showing steeper slopes that declined with increasing age, particularly after adolescence. In infants and toddlers, slopes continued to increase over 5 years of implant use, suggesting peripheral neural plasticity early in life. Older recipients showed minimal slope change over time. Although thresholds rose modestly with prolonged device use, slope and plateau stabilized after age 30 years, indicating that age at implantation, rather than stimulation duration, was the primary determinant of auditory nerve responsiveness. CONCLUSIONS AND RELEVANCE: This cohort study introduces a robust and scalable framework for in vivo assessment of auditory nerve function and monitoring of peripheral plasticity across the lifespan. The findings highlight the critical importance of early cochlear implantation for preserving neural health and optimizing long-term outcomes.
引用
- Larsen E, Litvak LM, Liberman MC, et al. Peripheral Neural Plasticity in Cochlear Implant Users Across the Lifespan. JAMA Otolaryngol Head Neck Surg. 2026. PMID: 41264293. doi:10.1001/jamaoto.2025.4050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。