舌下神经刺激上调期间可穿戴睡眠技术指标的变化
本病例系列在三级医疗中心纳入14例植入舌下神经刺激(HNS)的阻塞性睡眠呼吸暂停(OSA)患者,从设备激活至上调4个月内每晚使用Oura Ring采集睡眠与心脏指标,平均每人106±47晚、共1478晚数据。结果显示HNS振幅升高与入睡后觉醒时间(WASO)、平均心率(AvHR)及心率变异性(HRV)下降显著相关,总睡眠时间随时间增加但与HNS振幅变化无关。
要点
- HNS振幅升高与WASO下降显著相关(p=0.002)。
- HNS振幅升高与AvHR下降(p<0.001)和HRV下降(p<0.001)显著相关。
- 多变量亚组分析中HNS振幅增加与WASO下降(p=0.047)、AvHR和HRV降低(p=0.044,p=0.021)显著相关。
核心结论
- HNS上调可能与可穿戴消费级睡眠技术纵向追踪4个月所见的WASO、AvHR和HRV变化相关。
- 未来需要研究以理解HNS治疗对睡眠指标的影响,并探索CST在HNS治疗实施与结局评估中的临床效用。
研究设计与样本
- 本病例系列在三级医疗中心纳入14例因OSA植入HNS的参与者。
- 参与者从设备激活至上调期间每晚使用消费级睡眠技术(Oura Ring),持续4个月。
- 采用单变量和多变量回归模型评估指标,多变量模型控制年龄、性别、基线AHI和BMI。
主要发现
- 14例参与者平均每人采集106±47晚数据,共1478晚。
- HNS振幅升高与WASO下降显著相关(p=0.002)。
- HNS振幅升高与AvHR下降(p<0.001)和HRV下降(p<0.001)显著相关。
- 总睡眠时间随时间显著增加,但与HNS振幅变化无关联。
- 多变量亚组分析显示HNS振幅增加与WASO下降(p=0.047)、AvHR降低(p=0.044)和HRV降低(p=0.021)显著相关。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To pilot the use of a wearable consumer sleep technology (CST) for continuous, longitudinal assessment of sleep and cardiac metrics in patients undergoing hypoglossal nerve stimulation (HNS) uptitration for obstructive sleep apnea (OSA). METHODS: In this case series, participants implanted at a tertiary care center with HNS used a CST (Oura Ring) nightly, beginning at device activation through uptitration for 4 months. CST outcome metrics included total sleep time (TST), wake time after sleep onset (WASO), average heart rate (AvHR), heart rate variability (HRV), sleep efficiency, and latency. These metrics were evaluated using univariate and multivariate regression models controlling for age, sex, baseline apnea-hypopnea index (AHI), and body mass index (BMI). RESULTS: Fourteen participants had data on longitudinal HNS use and CST sleep data collected from an average of 106 ± 47 nights per participant (total 1478 nights of data). Higher HNS amplitudes were significantly associated with decreased WASO (p = 0.002), decreased AvHR (p < 0.001), and decreased HRV (p < 0.001). TST increased significantly over time but was not associated with HNS amplitude change. Multivariate analysis of a subgroup showed significant associations between HNS amplitude increases and a decline in WASO (p = 0.047) and reductions in AvHR and HRV (p = 0.044, p = 0.021). CONCLUSION: HNS uptitration may be associated with changes in WASO, AvHR, and HRV as tracked longitudinally over 4 months by a wearable CST. HNS uptitration was associated with changes in WASO, AvHR, and HRV. Future studies are needed to understand the effects of HNS therapy on sleep metrics and explore the clinical utility of CST in the paradigm of HNS therapy delivery and outcomes.
引用
- Singh A, Cai Y, Mason AE, et al. Changes in Wearable Sleep Technology Metrics During Hypoglossal Nerve Stimulation Uptitration. Laryngoscope. 2025. PMID: 40751537. doi:10.1002/lary.32465
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。