外视镜与显微镜在喉显微手术中手术时间与结局等效
该回顾性单中心研究纳入2019至2024年接受喉显微手术的84例患者(外视镜组45例、显微镜组39例),比较手术时间和嗓音结局。结果显示两组在准备时间、手术时长、总手术室时间及术后4-6周主观嗓音质量、OMNI嗓音努力和GRBAS各维度上均无统计学显著差异,两组均无严重并发症。
要点
- 外视镜组与显微镜组在准备时间、手术时长和总手术室时间上均无统计学显著差异。
- 术后4-6周主观嗓音质量、OMNI嗓音努力及GRBAS各维度两组均无统计学显著差异。
- 两组均无严重术中或术后并发症,外视镜在手术时间和嗓音结局上不劣于显微镜。
核心结论
- 外视镜在喉显微手术的手术时间和嗓音结局方面不劣于传统显微镜。
研究设计与样本
- 回顾性单中心研究,纳入2019至2024年接受喉显微手术并使用外视镜或显微镜的患者,共84例(外视镜组45例,显微镜组39例)。
主要发现
- 手术时间(分钟):外视镜组 vs 显微镜组准备时间22 vs 21(p=0.54),手术时长46 vs 49(p=0.45),总手术室时间83 vs 86(p=0.57)。
- 术前嗓音评估两组无显著差异。
- 术后4-6周主观嗓音质量7.8 vs 7.5(p=0.57),OMNI嗓音努力3.1 vs 3.9(p=0.28)。
- 术后4-6周GRBAS量表:G 0.80 vs 0.85(p=0.74),R 0.82 vs 0.72(p=0.46),B 0.26 vs 0.41(p=0.24),A 0.18 vs 0.10(p=0.36),S 0.56 vs 0.51(p=0.75)。
- 两组均无严重术中或术后并发症。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Newer optical systems such as 3D exoscopes are now being utilized for magnification and visualization in surgical fields like neurosurgery and otolaryngology. We seek to compare operative times and clinical outcomes between the operating exoscope (OE) and traditional operating microscopes (OM) for microlaryngeal surgery (MLS). METHODS: We conducted a retrospective, single-center review of patients who underwent MLS from 2019 to 2024 using the OE or OM, comparing operative times and voice outcome measures including patient subjective vocal quality, OMNI vocal effort, and GRBAS scales. RESULTS: Eighty-four (45 OE and 39 OM) patients underwent MLS for primarily phonotraumatic vocal fold lesions. There were no statistically significant differences in operative time (in minutes) between OE versus OM cohorts: setup time (22 vs. 21, p value = 0.54), procedure length (46 vs. 49, p = 0.45), and total patient time in OR (83 vs. 86, p = 0.57). There were no significant differences in pre-operative voice assessments between the OE and OM cohorts. There were also no significant differences in post-operative (4-6 weeks) subjective vocal quality (7.8 vs. 7.5, p = 0.57), OMNI vocal effort (3.1 vs. 3.9, p = 0.28), or GRBAS scale (G: 0.80 vs. 0.85, p = 0.74; R: 0.82 vs. 0.72, p = 0.46; B: 0.26 vs. 0.41, p = 0.24; A: 0.18 vs. 0.10, p = 0.36; S: 0.56 vs. 0.51, p = 0.75). There were no serious intraoperative or postoperative complications in either cohort. CONCLUSION: This is the first study directly comparing the OE to the OM in MLS. Our findings demonstrate non-inferiority of the OE compared to the OM for operative times and voice outcomes.
引用
- Mehdi Z, Kibel V, Momin N, et al. Exoscope and Microscope Show Equivalence in Operative Times and Outcomes for Microlaryngeal Surgery. Laryngoscope. 2025. PMID: 40590437. doi:10.1002/lary.32374
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。