使用Trachealator同时行上气道扩张与通气:技术要点与陷阱
单中心回顾性分析16例患者共18次非闭塞性上气道球囊扩张(NOBD),在监测麻醉护理(MAC,72.2%)或全身麻醉(GA,27.8%)下进行,平均扩张时长1.36分钟;2次MAC下NOBD需转为闭塞性球囊扩张,1次因球囊未完全扩张出现暂时性通气不足,无血氧饱和度下降事件。作者认为NOBD可作为闭塞性球囊扩张的安全替代方案。
要点
- NOBD平均扩张时长1.36分钟(范围0.5-3.0分钟),无血氧饱和度下降事件。
- GA下60%使用喉罩气道(LMA),40%使用喷射通气,无操作使用无呼吸通气。
- NOBD成功取决于球囊的解剖位置放置是否正确。
核心结论
- 非闭塞性球囊扩张可作为闭塞性球囊扩张的安全替代方案。
- 该装置在全身麻醉喷射通气、全身麻醉喉罩气道和清醒监测麻醉护理三种场景中均有效。
研究设计与样本
- 单中心回顾性研究,纳入在一家三级喉科中心接受非闭塞性上气道球囊扩张(NOBD)的患者。
- 共16例患者(平均年龄53岁,93.75%为女性)接受18次NOBD操作。
主要发现
- 18次NOBD中,监测麻醉护理(MAC)占72.2%,全身麻醉(GA)占27.8%。
- GA操作中,60%使用喉罩气道(LMA),40%使用喷射通气,无操作使用无呼吸通气。
- 2次MAC下NOBD需转为闭塞性球囊扩张(OBD)。
- 1次操作因非闭塞性球囊未完全扩张出现暂时性通气不足。
- NOBD期间未报告血氧饱和度下降事件,即使扩张时间超过1分钟。
临床怎么用
- NOBD成功取决于球囊的解剖位置放置是否正确。
- LMA通路需要专用的支气管封堵器适配器。
- 作者认为该装置在GA喷射通气、GA LMA和清醒MAC三种场景中均有效。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Balloon dilation is a method for treating laryngotracheal stenosis. This traditionally necessitates temporary airway occlusion, which requires apnea, carries the risk of barotrauma, and limits the duration of dilation. The Trachealator, a non-occlusive balloon, is designed to facilitate uninterrupted ventilation during dilation. This study presents a single institution experience with the Trachealator, encompassing its applications, technical nuances, and limitations. METHODS: Retrospective review identified patients who underwent non-occlusive upper airway balloon dilation (NOBD) at a tertiary laryngology center. Patient demographics, sedation type, ventilation method, intraoperative events, and clinical course were recorded. RESULTS: Sixteen patients (mean age = 53, 93.75% female) underwent 18 NOBD procedures under monitored anesthesia care (MAC, 72.2%) or general anesthesia (GA, 27.8%). Average NOBD duration was 1.36 min (0.5-3.0 min). Of GA procedures, 60% utilized laryngeal mask airway (LMA) while 40% underwent jet ventilation; no procedure used apneic ventilation. LMA approach required a specialized bronchial blocker adaptor. Two NOBD procedures under MAC required conversion to occlusive balloon dilation (OBD). NOBD success rate was predicated on proper anatomic placement. Temporary inadequate ventilation occurred in 1 procedure due to incomplete non-occlusive balloon inflation. No desaturation events were reported during NOBD even with > 1 min dilations. CONCLUSIONS: Non-occlusive balloon dilation can be a safe alternative to OBD. This study emphasizes key clinical insights regarding its use while also identifying potential challenges. This device has proven effective for upper airway dilation in three distinct settings: GA with jet ventilation, GA with LMA, and awake MAC. Each of these approaches has several unique technical aspects.
引用
- D'Oto AD, Marshall CR, Crosby TW, et al. Simultaneous Upper Airway Dilation and Ventilation With the Trachealator: Technical Pearls and Pitfalls. Laryngoscope. 2025. PMID: 40497639. doi:10.1002/lary.32302